Criterion Validity and Inter-Method Reliability of a Smartphone Sensor-Based Application for Lower-Limb Range of Motion: In-Person vs. Tele-Assessment
Sensors · 06.03.2026 · 26 (5) · 1661
DOI: 10.3390/s26051661 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.03.2026. Verfasst von Rehab Aljuhni und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy and Health Rehabilitation, College of Applied Medical Sciences, Majmaah University, Al Majmaah 15341, Saudi Arabia. Hauptthemen laut MEDLINE: Range of Motion, Articular, Smartphone, Lower Extremity. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Postgraduate and Scientific Research at Majmaah University.
Abstract (Originalsprache)
The increasing use of telerehabilitation has intensified the need for validated smartphone sensor-based tools capable of accurately capturing joint range of motion (ROM). This study examined the criterion validity of the PhysioMaster application compared with a universal goniometer during in-person assessments and evaluated the inter-method reliability between in-person and online PhysioMaster measurements. Thirty healthy young adults underwent standardized hip, knee, and ankle ROM testing using both approaches. The criterion validity was limited for most joints, with only ankle plantarflexion demonstrating the highest validity and dorsiflexion showing a moderate association; in contrast, hip and knee ROM exhibited poor agreement with goniometric values. Despite limited absolute agreement, PhysioMaster demonstrated moderate to good inter-method reliability for hip and knee ROM, indicating consistency across assessment modes. These findings suggest that while PhysioMaster may not serve as a direct substitute for in-person goniometry, it shows potential as a consistent tool for tracking ROM changes remotely, particularly for hip and knee movements. The application may support remote musculoskeletal monitoring within telerehabilitation contexts where repeated, standardized assessments are required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Therapy and Health Rehabilitation, College of Applied Medical Sciences, Majmaah University, Al Majmaah 15341, Saudi Arabia.
ORCID-Profile: Rehab Aljuhni, Zainab Aldarwish, Shroug Almutairi
Förderung
- Deanship of Postgraduate and Scientific Research at Majmaah University
Zitieren
APA
Aljuhni, R., Aldarwish, Z., & Almutairi, S. (2026). Criterion Validity and Inter-Method Reliability of a Smartphone Sensor-Based Application for Lower-Limb Range of Motion: In-Person vs. Tele-Assessment. Sensors, 26(5), 1661. https://doi.org/10.3390/s26051661
Vancouver
Aljuhni R, Aldarwish Z, Almutairi S. Criterion Validity and Inter-Method Reliability of a Smartphone Sensor-Based Application for Lower-Limb Range of Motion: In-Person vs. Tele-Assessment. Sensors. 2026;26(5):1661. doi:10.3390/s26051661
BibTeX
@article{Aljuhni2026,
author = {Aljuhni, Rehab and Aldarwish, Zainab and Almutairi, Shroug},
title = {Criterion Validity and Inter-Method Reliability of a Smartphone Sensor-Based Application for Lower-Limb Range of Motion: In-Person vs. Tele-Assessment},
journal = {Sensors},
year = {2026},
volume = {26},
number = {5},
pages = {1661},
doi = {10.3390/s26051661}
}
EUVIMED