EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Reliability of range of motion in straight leg raise and hip extension tests among healthy young adults using a smartphone application

Tetsuya Amano, Nobuhide Agata, Takeshi Yamamoto, Keisuke Mori

Journal of Bodywork and Movement Therapies · 2024

DOI: 10.1016/j.jbmt.2024.05.033 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Bodywork and Movement Therapies, 2024. Verfasst von Tetsuya Amano und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, Faculty of Health and Medical Sciences, Tokoha University, Hamamatsu, Shizuoka, Japan. Electronic address: tamano@hm.…. Hauptthemen laut MEDLINE: Range of Motion, Articular, Smartphone, Mobile Applications. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Measuring range of motion (ROM) is an important skill for clinicians because it can help in the accurate interpretation of a patient's condition. Recently, ROM tests using smartphone applications have been performed in clinical settings, with the tests demonstrating high reliability and validity. This study aimed to identify the usefulness of ROM tests conducted using smartphone applications by examining the reliability of straight leg raise (SLR) and hip extension (HE) tests. METHODS: This cross-sectional observational study included 72 lower limbs of 36 participants (19 men and 17 women; mean age, 21.6 ± 0.8 years). Passive SLR-ROM and HE-ROM were measured in 1° increments using an iPhone goniometer (IG). Intra-rater and inter-rater reliabilities were calculated using intraclass correlation coefficients (ICCs). ROM test systematic error was confirmed using Bland-Altman analysis, and ROM measurement error was calculated. RESULTS: The ICCs of the IG ROM tests were 0.820 or higher. According to Bland-Altman analyses, SLR-ROM and HE-ROM did not acknowledge fixed and proportional biases. Thus, ROM measurement error was calculated as the minimal detectable change (MDC). The intra-rater and inter-rater MDC 95% confidence interval (MDC95) values of SLR-ROM were 3.3° and 10.2°, respectively. The intra-rater and inter-rater MDC95 values for HE-ROM were 3.9° and 9.6°, respectively. CONCLUSION: IG ROM tests were highly reliable, simple, and easy to perform. SLR-ROM and HE-ROM tests conducted using smartphone applications may be useful indices for clinical decision-making.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Range of Motion, ArticularSmartphoneMobile ApplicationsHumansMaleFemaleCross-Sectional StudiesReproducibility of ResultsYoung AdultHip JointArthrometry, ArticularLegAdult

Stichwörter der Autor:innen

Clinical decision-makingDisability evaluationRange of motionRehabilitation

Autor:innen und Institutionen

  • Department of Physical Therapy, Faculty of Health and Medical Sciences, Tokoha University, Hamamatsu, Shizuoka, Japan. Electronic address: tamano@hm.tokoha-u.ac.jp.
  • Department of Physical Therapy, Faculty of Health and Medical Sciences, Tokoha University, Hamamatsu, Shizuoka, Japan.
  • Department of Judo Therapy, Asahi Medical College, Okayama, Okayama, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Amano, T., Agata, N., Yamamoto, T., & Mori, K. (2024). Reliability of range of motion in straight leg raise and hip extension tests among healthy young adults using a smartphone application. Journal of Bodywork and Movement Therapies. https://doi.org/10.1016/j.jbmt.2024.05.033

Vancouver

Amano T, Agata N, Yamamoto T, Mori K. Reliability of range of motion in straight leg raise and hip extension tests among healthy young adults using a smartphone application. Journal of Bodywork and Movement Therapies. 2024. doi:10.1016/j.jbmt.2024.05.033

BibTeX
@article{Amano2024,
  author = {Amano, Tetsuya and Agata, Nobuhide and Yamamoto, Takeshi and Mori, Keisuke},
  title = {Reliability of range of motion in straight leg raise and hip extension tests among healthy young adults using a smartphone application},
  journal = {Journal of Bodywork and Movement Therapies},
  year = {2024},
  doi = {10.1016/j.jbmt.2024.05.033}
}