Measuring Lower-Limb Kinematics in Walking: Wearable Sensors Achieve Comparable Reliability to Motion Capture Systems and Smartphone Cameras
Sensors · 2025
DOI: 10.3390/s25092899 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Peiyu Ma und 4 weiteren Autor:innen. Beteiligte Einrichtung: Dyson School of Design Engineering, Imperial College London, London SW7 2AZ, UK. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Lower Extremity, Walking, Smartphone. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
Marker-based, IMU-based (6-axis IMU), and smartphone-based (OpenCap) motion capture methods are commonly used for motion analysis. The accuracy and reliability of these methods are crucial for applications in rehabilitation and sports training. This study compares the accuracy and inter-operator reliability of inverse kinematics (IK) solutions obtained from these methods, aiming to assist researchers in selecting the most appropriate system. For most lower limb inverse kinematics during walking motion, the IMU-based method and OpenCap show comparable accuracy to marker-based methods. The IMU-based method demonstrates higher accuracy in knee angle (5.74 ± 0.80 versus 7.36 ± 3.14 deg, with p = 0.020) and ankle angle (7.47 ± 3.91 versus 8.20 ± 3.00 deg, with p = 0.011), while OpenCap shows higher accuracy than IMU in pelvis tilt (5.49 ± 2.22 versus 4.28 ± 1.47 deg, with p = 0.013), hip adduction (6.10 ± 1.35 versus 4.06 ± 0.78 deg, with p = 0.019) and hip rotation (6.09 ± 1.74 versus 4.82 ± 2.30 deg, with p = 0.009). The inter-operator reliability of the marker-based method and the IMU-based method shows no significant differences in most motions except for hip adduction (evaluated by the intraclass correlation coefficient-ICC, 0.910 versus 0.511, with p = 0.016). In conclusion, for measuring lower-limb kinematics, wearable sensors (6-axis IMUs) achieve comparable accuracy and reliability to the gold standard, marker-based motion capture method, with lower equipment requirements and fewer movement constraints during data acquisition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dyson School of Design Engineering, Imperial College London, London SW7 2AZ, UK.
- School of Engineering, University of Birmingham, Birmingham B15 2TT, UK.
- School of Sport, Exercise & Rehabilitation, University of Birmingham, Birmingham B15 2TT, UK.
ORCID-Profile: Peiyu Ma, Ziyun Ding
Förderung
- Engineering and Physical Sciences Research Council
Zitieren
APA
Ma, P., Bian, Q., Kim, J. M., Alsayed, K., & Ding, Z. (2025). Measuring Lower-Limb Kinematics in Walking: Wearable Sensors Achieve Comparable Reliability to Motion Capture Systems and Smartphone Cameras. Sensors. https://doi.org/10.3390/s25092899
Vancouver
Ma P, Bian Q, Kim JM, Alsayed K, Ding Z. Measuring Lower-Limb Kinematics in Walking: Wearable Sensors Achieve Comparable Reliability to Motion Capture Systems and Smartphone Cameras. Sensors. 2025. doi:10.3390/s25092899
BibTeX
@article{Ma2025,
author = {Ma, Peiyu and Bian, Qingyao and Kim, Jin Min and Alsayed, Khalid and Ding, Ziyun},
title = {Measuring Lower-Limb Kinematics in Walking: Wearable Sensors Achieve Comparable Reliability to Motion Capture Systems and Smartphone Cameras},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25092899}
}
EUVIMED