EUVIMEDEUVIMED entdecken
Vergleichsstudie

Inclinometers and Apps Are Better than Goniometers, Measuring Knee Extension Range of Motion in Anterior Cruciate Ligament Patients: Reliability and Minimal Detectable Change for the Three Devices

Michail Pantouveris, Roula Kotsifaki, Rodney Whiteley

The Journal of Knee Surgery · 01.10.2024 · 37 (12) · 821-827

DOI: 10.1055/a-2321-0516 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.10.2024. Verfasst von Michail Pantouveris und 2 weiteren Autor:innen. Beteiligte Einrichtung: Rehabilitation Department, Aspetar, Orthopaedic and Sports Medicine Hospital, Doha, Qatar. Hauptthemen laut MEDLINE: Range of Motion, Articular, Arthrometry, Articular, Mobile Applications, Anterior Cruciate Ligament Injuries. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Knee extension range of motion (ROM) measurement is important in patients with anterior cruciate ligament (ACL) injury. The main objective is to evaluate the reliability and the minimal detectable change (MDC) of three methods of measuring knee extension ROM in ACL patients. The three common goniometric devices were a universal goniometer, an inclinometer, and a smartphone app. During a single-visit, knee extension ROM was measured in both knees of 92 ACL-injured or -reconstructed patients by two testers blinded to the other's measures. Intrarater, interrater, and test–retest intraclass correlation coefficients (ICC2,1) were calculated. Intrarater ICC2,1 was excellent for the three devices ranging from 0.92 to 0.94, with the inclinometer yielding the best results (ICC2,1 = 0.94 [95% confidence interval, CI: 0.91–0.96]). Interrater ICC2,1, however, varied from 0.36 to 0.80. The inclinometer and the smartphone app yielded similar results 0.80 (95% CI: 0.71–0.86) and 0.79 (95% CI: 0.70–0.86), respectively, whereas the universal goniometer was 0.36 (95% CI: 0.17–0.53). Test–retest ICC2,1 for the inclinometer was 0.89 (95% CI: 0.84–0.93), 0.86 (95% CI: 0.79–0.91) for the app, and 0.83 (95% CI:0.74–0.89) for the goniometer. The intrarater, interrater, and test–retest MDC95 values ranged from 2.0 to 3.5, 3.7 to 10.4, and 2.6 to 5.4 degrees, respectively. The goniometer was the least reliable. The inclinometer is the recommended device due to its highest ICC scores among the three devices and ease of use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Range of Motion, ArticularArthrometry, ArticularMobile ApplicationsAnterior Cruciate Ligament InjuriesHumansReproducibility of ResultsMaleAdultFemaleKnee JointYoung AdultAnterior Cruciate LigamentMiddle AgedSmartphoneAnterior Cruciate Ligament ReconstructionAdolescent

Autor:innen und Institutionen

  • Rehabilitation Department, Aspetar, Orthopaedic and Sports Medicine Hospital, Doha, Qatar.
  • Department of Sports Medicine, Oslo Sports Trauma Research Center, Norwegian School of Sport Sciences, Oslo, Norway.

Zitieren

APA

Pantouveris, M., Kotsifaki, R., & Whiteley, R. (2024). Inclinometers and Apps Are Better than Goniometers, Measuring Knee Extension Range of Motion in Anterior Cruciate Ligament Patients: Reliability and Minimal Detectable Change for the Three Devices. The Journal of Knee Surgery, 37(12), 821-827. https://doi.org/10.1055/a-2321-0516

Vancouver

Pantouveris M, Kotsifaki R, Whiteley R. Inclinometers and Apps Are Better than Goniometers, Measuring Knee Extension Range of Motion in Anterior Cruciate Ligament Patients: Reliability and Minimal Detectable Change for the Three Devices. The Journal of Knee Surgery. 2024;37(12):821-827. doi:10.1055/a-2321-0516

BibTeX
@article{Pantouveris2024,
  author = {Pantouveris, Michail and Kotsifaki, Roula and Whiteley, Rodney},
  title = {Inclinometers and Apps Are Better than Goniometers, Measuring Knee Extension Range of Motion in Anterior Cruciate Ligament Patients: Reliability and Minimal Detectable Change for the Three Devices},
  journal = {The Journal of Knee Surgery},
  year = {2024},
  volume = {37},
  number = {12},
  pages = {821--827},
  doi = {10.1055/a-2321-0516}
}
Kostenlos starten →