EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity and Reliability of Gait Speed and Knee Flexion Estimated by a Novel Vision-Based Smartphone Application

Kam Lun Leung, Zongpan Li, Chen Huang, Xiuping Huang, Siu Ngor Fu

Sensors · 2024

DOI: 10.3390/s24237625 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Kam Lun Leung und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong, China. Hauptthemen laut MEDLINE: Smartphone, Mobile Applications, Walking Speed. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Hong Kong Jockey Charities Trust, Hong Kong Jockey Club Charities Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Patients with knee osteoarthritis walk with reduced speed and knee flexion excursion in the early stance phase. A slow walking speed is also associated with falls in older adults. A novel vision-based smartphone application could potentially facilitate the early detection of knee osteoarthritis and fall prevention. This study aimed to test the validity and reliability of the app-captured gait speed and peak knee flexion during the initial stance phase of gait. Twenty adults (aged 23–68 years) walked at self-selected comfortable walking speeds while the gait speed and knee flexion were simultaneously measured using retroreflective sensors and Xsens motion trackers and the app in two separate sessions for validity and reliability tests. Pearson’s r correlation and Bland–Altman plots were used to examine the correlations and agreements between the sensor- and app-measured outcomes. One-sample t-tests were performed to examine whether systematic bias existed. The intraclass correlation coefficient (ICC) was calculated to assess the test–retest reliability of the app. Very high correlations were found between the sensor and app measurements for gait speed (r = 0.98, p < 0.001) and knee flexion (r = 0.91–0.92, all p < 0.001). No significant bias was detected for the final app version. The app also showed a good to excellent test–retest reliability for measuring the gait speed and peak knee flexion (ICC = 0.86–0.94). This vision-based smartphone application is valid and reliable for capturing the walking speed and knee flexion during the initial stance of gait, potentially aiding in the early detection of knee osteoarthritis and fall prevention in community living locations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneMobile ApplicationsWalking SpeedHumansMiddle AgedMaleAdultFemaleAgedGaitReproducibility of ResultsOsteoarthritis, KneeYoung AdultKnee JointWalkingRange of Motion, Articular

Stichwörter der Autor:innen

fallknee flexionknee osteoarthritissmartphone applicationwalking speed

Autor:innen und Institutionen

  • Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong, China.

Förderung

  • The Hong Kong Jockey Charities Trust
  • Hong Kong Jockey Club Charities Trust

Zitieren

APA

Leung, K. L., Li, Z., Huang, C., Huang, X., & Fu, S. N. (2024). Validity and Reliability of Gait Speed and Knee Flexion Estimated by a Novel Vision-Based Smartphone Application. Sensors. https://doi.org/10.3390/s24237625

Vancouver

Leung KL, Li Z, Huang C, Huang X, Fu SN. Validity and Reliability of Gait Speed and Knee Flexion Estimated by a Novel Vision-Based Smartphone Application. Sensors. 2024. doi:10.3390/s24237625

BibTeX
@article{Leung2024,
  author = {Leung, Kam Lun and Li, Zongpan and Huang, Chen and Huang, Xiuping and Fu, Siu Ngor},
  title = {Validity and Reliability of Gait Speed and Knee Flexion Estimated by a Novel Vision-Based Smartphone Application},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24237625}
}
Kostenlos starten →