Fachartikel in der Zeitschrift Methods and Protocols, online erschienen am 09.03.2023. Verfasst von Juho Tuominen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Facualty of Medicine and Health Technology, Tampere University, 33014 Tampere, Finland. Die Arbeit wurde bisher 64-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Finnish Ministry of Education and Culture.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The isokinetic dynamometry is considered a gold standard in muscle strength testing. The reliability of lower limb isokinetic strength measurements has not been thoroughly evaluated.

Objective

To examine the test−retest reliability of isokinetic ankle plantar and dorsiflexion, ankle inversion and eversion, knee extension and flexion and hip abduction and adduction strength in physically active adults using Biodex System 4 Pro.

Methods

Peak torques (PTs) and average peak torques (APTs) of the dominant and nondominant lower limbs were tested twice in 19 physically active adults 7 to 14 days apart.

Results

The intraclass correlation coefficients (ICC) values varied from excellent to moderate and coefficient of variation of typical error (CVTE) values were 6.6–19.5%. Change in the mean expressed as a percent varied from −3.1% to 9.6%. There was no difference in the reliability between PT and APT values. Dominant lower limb was more reliable in every case if there was difference between limbs.

Conclusion

Test−retest reliability of isokinetic ankle, knee and hip strength in physically active adults using Biodex System 4 is mostly good or excellent. However, the observed range of the random variation has to be noted when using it in scientific follow-up studies or evaluation of patient progress in clinical settings.

Schlagwörter

Stichwörter der Autor:innen

Biodexankledynamometryhipisokinetickneereliabilitytest−retest

Autor:innen und Institutionen

  • Facualty of Medicine and Health Technology, Tampere University, 33014 Tampere, Finland.
  • Tampere Research Center of Sports Medicine, UKK Institute for Health Promotion Research, 33500 Tampere, Finland.
  • Tampere University Hospital, 33520 Tampere, Finland.
  • Sport Injury Prevention Research Centre, Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada.
  • Alberta Children's Hospital Research Institute, University of Calgary, Calgary, AB T2N 1N4, Canada.
  • McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada.

ORCID-Profile: Juho Tuominen, Mari Leppänen, Tommi Vasankari

Förderung

  • Finnish Ministry of Education and Culture

Zitieren

APA

Tuominen, J., Leppänen, M., Jarske, H., Pasanen, K., Vasankari, T., & Parkkari, J. (2023). Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro. Methods and Protocols, 6(2), 26. https://doi.org/10.3390/mps6020026

Vancouver

Tuominen J, Leppänen M, Jarske H, Pasanen K, Vasankari T, Parkkari J. Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro. Methods and Protocols. 2023;6(2):26. doi:10.3390/mps6020026

BibTeX
@article{Tuominen2023,
  author = {Tuominen, Juho and Leppänen, Mari and Jarske, Heidi and Pasanen, Kati and Vasankari, Tommi and Parkkari, Jari},
  title = {Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro},
  journal = {Methods and Protocols},
  year = {2023},
  volume = {6},
  number = {2},
  pages = {26},
  doi = {10.3390/mps6020026}
}
Kostenlos starten →