EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the reliability of a digital inclinometer app for measuring hip, knee, and ankle proprioception

Sophia G Chirumbole, Rachel H Teater iD, Megan M Bals, Daniel R Richie, Scott M Monfort iD, Ajit M W Chaudhari iD

PLOS ONE · 23.09.2024 · 19 (9) · e0308737

DOI: 10.1371/journal.pone.0308737 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 23.09.2024. Verfasst von Sophia G Chirumbole und 5 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical & Aerospace Engineering, Ohio State University, Columbus, Ohio, United States of America. Hauptthemen laut MEDLINE: Proprioception, Knee Joint, Ankle Joint, Hip Joint. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIA NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Proprioception can be defined as the ability of an individual to detect motion and position of the various joints in their bodies. Current tools for measuring proprioception lack consensus on their accuracy and validity; they also each have their own limitations, and, furthermore, present barriers to use for clinicians. We propose a new and reliable method for evaluating hip, knee, and ankle proprioception by utilizing a digital inclinometer app to measure joint position sense. The digital inclinometer app recorded the active joint position sense error after each of five trials for the hip and knee joint and ten trials for the ankle joint. To quantify the reliability of the digital inclinometer app, single-measurement and average-measurement intra-class correlation coefficients (ICC) along with the associated 95% confidence intervals (95% CI) were calculated for each joint’s position sense error across trials. Both the hip (ICC (2,k) = 0.849 (95% CI = [0.783–0.897])) and knee joint (ICC (2,k) = 0.837 (95% CI = [0.750–0.897])) were found to have moderate to good reliability when the middle three of five trials were analyzed. Unlike the hip and knee, moderate to good reliability for ankle proprioception (ICC (2,k) = 0.785 (95% CI = [0.539–0.893])) was only achieved with the middle eight of ten trials. The results of this study indicate that this digital inclinometer app is able to accurately record joint position sense at the hip, knee, and ankle when the appropriate number of trials are collected; thus, allowing this tool and methodology to be considered for use in both clinical and research environments to measure proprioception, and furthermore, quantify proprioceptive deficits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProprioceptionKnee JointAnkle JointHip JointHumansReproducibility of ResultsMaleFemaleAdultMobile ApplicationsRange of Motion, ArticularYoung Adult

Autor:innen und Institutionen

  • Mechanical & Aerospace Engineering, Ohio State University, Columbus, Ohio, United States of America.
  • Mechanical Engineering, Vanderbilt University, Nashville, Tennessee, United States of America.
  • Physical Therapy, NovaCare Rehabilitation, United States of America.
  • Biomedical Engineering, Ohio State University, Columbus, Ohio, United States of America.
  • Mechanical & Industrial Engineering, Montana State University, Bozeman, Montana, United States of America.
  • Health and Rehabilitation Sciences, Ohio State University, Columbus, Ohio, United States of America.

ORCID-Profile: Rachel H Teater, Scott M Monfort, Ajit M W Chaudhari

Förderung

  • NIA NIH HHS

Zitieren

APA

Chirumbole, S. G., Teater, R. H., Bals, M. M., Richie, D. R., Monfort, S. M., & Chaudhari, A. M. W. (2024). Assessing the reliability of a digital inclinometer app for measuring hip, knee, and ankle proprioception. PLOS ONE, 19(9), e0308737. https://doi.org/10.1371/journal.pone.0308737

Vancouver

Chirumbole SG, Teater RH, Bals MM, Richie DR, Monfort SM, Chaudhari AMW. Assessing the reliability of a digital inclinometer app for measuring hip, knee, and ankle proprioception. PLOS ONE. 2024;19(9):e0308737. doi:10.1371/journal.pone.0308737

BibTeX
@article{Chirumbole2024,
  author = {Chirumbole, Sophia G and Teater, Rachel H and Bals, Megan M and Richie, Daniel R and Monfort, Scott M and Chaudhari, Ajit M W},
  title = {Assessing the reliability of a digital inclinometer app for measuring hip, knee, and ankle proprioception},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {9},
  pages = {e0308737},
  doi = {10.1371/journal.pone.0308737}
}
Kostenlos starten →