EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY-NC 4.0

Reliability of a Standardized Isokinetic Knee Strength Protocol Across a Slow–Fast Velocity Spectrum in Physically Active Adults with the Biodex System 4 Pro

Jesper Augustsson iD, Jannie Strågegård, Elin Peterson, Ted Gunhamn

International Journal of Sports Physical Therapy · 01.10.2026 · 21 (10)

DOI: 10.26603/001c.169848 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift International Journal of Sports Physical Therapy, online erschienen am 01.10.2026. Verfasst von Jesper Augustsson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport Science Linnaeus University. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Isokinetic dynamometry is widely used to assess knee muscle strength in both clinical and athletic settings; however, the reliability of measurements across different angular velocities representing distinct regions of the force–velocity spectrum requires further investigation.

Purpose

To examine the test–retest reliability of concentric isokinetic knee extension and flexion strength at slow and fast angular velocities using the Biodex System 4. Study Design Repeated measures.

Methods

A total of 15 healthy, physically active adults, women (n=7) and men (n=8), within the age range 21–34 years (inclusion criterion: 18–40 years) participated in the study. Each subject completed two test sessions spaced one week apart. Peak torques of the dominant leg during knee extension and flexion were measured using the Biodex System 4 at angular velocities of 90°/s and 180°/s. Reliability was analyzed using intraclass correlation coefficient (ICC) with 95% confidence intervals and the coefficient of variation (CV).

Results

The results showed high to very high reliability across all test conditions (ICC = 0.92–0.99; 95% CI: 0.78–1.00). CV values ranged from 2.7% to 4.2%, and no significant differences in peak torque were observed between test sessions.

Conclusion

The isokinetic measurements were reliable at both 90°/s and 180°/s, supporting their use in rehabilitation and strength training evaluations. As distinct strength qualities exist and muscle performance can be assessed across a dynamic velocity spectrum, isokinetic testing at multiple angular velocities may provide a more comprehensive characterization of muscle function than a single-speed assessment alone. Level of Evidence 2

Schlagwörter

Stichwörter der Autor:innen

angular velocityintraclass correlation coefficientisokinetic dynamometryknee extensor strengthknee flexor strengthtest–retest reliability

Autor:innen und Institutionen

  • Department of Sport Science Linnaeus University.

ORCID-Profile: Jesper Augustsson

Zitieren

APA

Augustsson, J., Strågegård, J., Peterson, E., & Gunhamn, T. (2026). Reliability of a Standardized Isokinetic Knee Strength Protocol Across a Slow–Fast Velocity Spectrum in Physically Active Adults with the Biodex System 4 Pro. International Journal of Sports Physical Therapy, 21(10). https://doi.org/10.26603/001c.169848

Vancouver

Augustsson J, Strågegård J, Peterson E, Gunhamn T. Reliability of a Standardized Isokinetic Knee Strength Protocol Across a Slow–Fast Velocity Spectrum in Physically Active Adults with the Biodex System 4 Pro. International Journal of Sports Physical Therapy. 2026;21(10). doi:10.26603/001c.169848

BibTeX
@article{Augustsson2026,
  author = {Augustsson, Jesper and Strågegård, Jannie and Peterson, Elin and Gunhamn, Ted},
  title = {Reliability of a Standardized Isokinetic Knee Strength Protocol Across a Slow–Fast Velocity Spectrum in Physically Active Adults with the Biodex System 4 Pro},
  journal = {International Journal of Sports Physical Therapy},
  year = {2026},
  volume = {21},
  number = {10},
  doi = {10.26603/001c.169848}
}