The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals
Physiotherapy Research International · 2026-04 · 31 (2)
DOI: 10.1002/pri.70171 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiotherapy Research International, online erschienen am 11.02.2026. Verfasst von Merve Keskin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, İzmir Katip Celebi University, İzmir, Türkiye. Hauptthemen laut MEDLINE: Reaction Time, Upper Extremity, Psychomotor Performance, Motor Skills. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
Background and Purpose To determine the test‐retest reliability and minimal detectable change of the Brain Pro System (Brain Pro System, Poland) for assessing upper extremity visuo‐motor reaction time (V‐MRT) in physically active healthy individuals.
Methods
Sixty‐four physically active healthy participants (M age = 21.26, SD = 0.94 years) completed two assessments 1 week apart. Reliability was assessed using ICC2,1 with a 95% confidence interval. The standard error of measurement and MDC95 were calculated. Stability was analyzed with Cronbach's α and coefficient of variation (CV).
Results
The Brain Pro System demonstrated excellent reliability for right, left, and randomly determined upper extremity V‐MRT (ICC2,1 = 0.95–0.97, α = 0.95–0.97, CV = 0.01). The MDC values were 1.21 s for right and left V‐MRT and 1.10 s for combined extremities.
Discussion
The Brain Pro System is highly reliable for assessing V‐MRT. The MDC values provide a reference for evaluating meaningful changes in reaction time for physically active, healthy adults.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, İzmir Katip Celebi University, İzmir, Türkiye.
- Physiotherapy and Rehabilitation Application and Research Center, İzmir Katip Celebi University, İzmir, Türkiye.
- Department of Health Care Services, Vocational School of Health Services, Manisa Celal Bayar University, Manisa, Türkiye.
ORCID-Profile: Merve Keskin
Zitieren
APA
Keskin, M., Secer, E., & Kaya, D. O. (2026). The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals. Physiotherapy Research International, 31(2). https://doi.org/10.1002/pri.70171
Vancouver
Keskin M, Secer E, Kaya DO. The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals. Physiotherapy Research International. 2026;31(2). doi:10.1002/pri.70171
BibTeX
@article{Keskin2026,
author = {Keskin, Merve and Secer, Erhan and Kaya, Derya Ozer},
title = {The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals},
journal = {Physiotherapy Research International},
year = {2026},
volume = {31},
number = {2},
doi = {10.1002/pri.70171}
}