EUVIMEDEUVIMED entdecken
Open Access

Test-retest reliability and concurrent validity of three different handgrip dynamometers (Jamar, Jamar Plus+ and Biodex) in healthy young adults

Gabriel Morais Xavier Dos Santos iD, Leonardo Dutra de Salvo Mauad iD, Heloísa Corrêa Bueno Nardim iD, Mariana Ferreira Silva, Flávia Pessoni Faleiros Macedo iD, Gabriela Rezende iD, Raquel Metzker Mendes Sugano iD, Elaine Caldeira de Oliveira Guirro iD, Marisa de Cássia Registro Fonseca iD

Hand Therapy · 2026-03 · 31 (1) · 29-44

DOI: 10.1177/17589983251352104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hand Therapy, online erschienen am 05.07.2025. Verfasst von Gabriel Morais Xavier Dos Santos und 8 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Programme in Rehabilitation and Performance, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 86 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Handgrip strength (HGS) is a key indicator of upper limb function and overall health. While the Jamar dynamometer is considered the gold standard for HGS assessment, alternatives like the Jamar Plus+ and Biodex have emerged, though their reliability and agreement remain underexplored.

Aim

To evaluate the test–retest reliability and agreement of the Jamar, Jamar Plus+, and Biodex dynamometers in healthy young adults.

Methods

This exploratory cross-sectional study included 35 participants (22 females, 13 males; mean age 23.4 years). HGS was assessed using the three devices, following standardised protocols, with retest after 7 days. Reliability was analysed using the Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM), and Minimal Detectable Change (MDC). Agreement was examined through Bland–Altman plots and Limits of Agreement (LoA %).

Results

Jamar and Jamar Plus+ showed excellent reliability (ICC = 0.96–0.98) and strong agreement, with narrow LoA percentages and low measurement error, especially on the non-dominant hand. In contrast, comparisons involving the Biodex revealed wider LoA (up to ±73%) and higher SEM and MDC values, indicating lower agreement with handheld devices. These discrepancies are likely due to differences in measurement principles, hand positioning, and unit conversion. Male participants showed significantly higher grip strength across all instruments.

Conclusion

The Jamar and Jamar Plus+ can be used interchangeably. The Biodex may be considered when appropriate adjustments are made, though its agreement with handheld dynamometers is limited. These findings highlight the need for standardised protocols and further research to ensure consistent and reliable HGS assessment across devices.

Schlagwörter

Stichwörter der Autor:innen

Handgrip strengthdynamometryreliability

Autor:innen und Institutionen

  • Postgraduate Programme in Rehabilitation and Performance, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil.
  • Division of Occupational Therapy, Department of Health Sciences, Ribeirão Preto Medical School, University of São Paulo (FMRP - USP), Ribeirão Preto, Brazil.
  • Division of Physical Therapy, Department of Health Sciences, Ribeirão Preto Medical School, University of São Paulo (FMRP - USP), Ribeirão Preto, Brazil.

ORCID-Profile: Gabriel Morais Xavier Dos Santos, Leonardo Dutra de Salvo Mauad, Heloísa Corrêa Bueno Nardim, Flávia Pessoni Faleiros Macedo, Gabriela Rezende, Raquel Metzker Mendes Sugano, Elaine Caldeira de Oliveira Guirro, Marisa de Cássia Registro Fonseca

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Dos Santos, G. M. X., Mauad, L. D. S., Nardim, H. C. B., Silva, M. F., Faleiros Macedo, F. P., Rezende, G., Mendes Sugano, R. M., Guirro, E. C. O., & de Cássia Registro Fonseca, M. (2026). Test-retest reliability and concurrent validity of three different handgrip dynamometers (Jamar, Jamar Plus+ and Biodex) in healthy young adults. Hand Therapy, 31(1), 29-44. https://doi.org/10.1177/17589983251352104

Vancouver

Dos Santos GMX, Mauad LDS, Nardim HCB, Silva MF, Faleiros Macedo FP, Rezende G, et al. Test-retest reliability and concurrent validity of three different handgrip dynamometers (Jamar, Jamar Plus+ and Biodex) in healthy young adults. Hand Therapy. 2026;31(1):29-44. doi:10.1177/17589983251352104

BibTeX
@article{DosSantos2026,
  author = {Dos Santos, Gabriel Morais Xavier and Mauad, Leonardo Dutra de Salvo and Nardim, Heloísa Corrêa Bueno and Silva, Mariana Ferreira and Faleiros Macedo, Flávia Pessoni and Rezende, Gabriela and Mendes Sugano, Raquel Metzker and Guirro, Elaine Caldeira de Oliveira and de Cássia Registro Fonseca, Marisa},
  title = {Test-retest reliability and concurrent validity of three different handgrip dynamometers (Jamar, Jamar Plus+ and Biodex) in healthy young adults},
  journal = {Hand Therapy},
  year = {2026},
  volume = {31},
  number = {1},
  pages = {29--44},
  doi = {10.1177/17589983251352104}
}
Kostenlos starten →