Effect of Implant Macro-Design and Magnetodynamic Surgical Preparation on Primary Implant Stability: An In Vitro Investigation
Dentistry Journal · 24.09.2023 · 11 (10) · 227
DOI: 10.3390/dj11100227 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 24.09.2023. Verfasst von Alessandro Antonelli und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, Department of Health Sciences, Magna Graecia University of Catanzaro, 88100 Catanzaro, Italy. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Macro-geometry and surgical implant site preparation are two of the main factors influencing implant stability and potentially determining loading protocol. The purpose of this study was to assess the initial stability of various implant macro-designs using both magnetodynamic and traditional osteotomy techniques in low-density bone. The parameters examined included peak insertion torque (PIT), implant stability quotient (ISQ), and peak removal torque (PRT).
Methods
Four groups of 34 implants each were identified in accordance with the surgery and implant shape: T5 group (Five implant and osteotomy using drills); M5 group (Five implant and magnetodynamic osteotomy using Magnetic Mallet); TT group (TiSmart implant and osteotomy with drills); and MT group (TiSmart implant and magnetodynamic osteotomy). Every implant was placed into a low-density bone animal model and scanned using CBCT. The PIT and PRT were digitally measured in Newton-centimeters (Ncm) using a torque gauge device. The ISQ was analyzed by conducting resonance frequency analysis.
Results
The PIT values were 25.04 ± 4.4 Ncm for T5, 30.62 ± 3.81 Ncm for M5, 30 ± 3.74 Ncm for TT, and 32.05 ± 3.55 Ncm for MT. The average ISQ values were 68.11 ± 3.86 for T5, 71.41 ± 3.69 for M5, 70.88 ± 3.08 for TT, and 73 ± 3.5 for MT. The PRT values were 16.47 ± 4.56 Ncm for T5, 26.02 ± 4.03 Ncm for M5, 23.91 ± 3.28 Ncm for TT, and 26.93 ± 3.96 Ncm for MT. Based on our data analysis using a t-test with α = 0.05, significant differences in PIT were observed between TT and T5 (p < 0.0001), M5 and T5 (p < 0.0001), and MT and TT (p = 0.02). Significant differences in the ISQ were found between TT and T5 (p = 0.001), M5 and T5 (p < 0.001), and MT and TT (p = 0.01). The PRT also exhibited significant differences between TT and T5, M5 and T5, and MT and TT (p < 0.0001).
Conclusion
Our data showed favorable primary implant stability (PS) values for both implant macro-geometries. Furthermore, the magnetodynamic preparation technique appears to be more effective in achieving higher PS values in low-density bone.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Dentistry, Department of Health Sciences, Magna Graecia University of Catanzaro, 88100 Catanzaro, Italy.
ORCID-Profile: Alessandro Antonelli, Ferdinando Attanasio, Elena Calabria, Francesco Bennardo, Amerigo Giudice
Zitieren
APA
Antonelli, A., Barone, S., Attanasio, F., Salviati, M., Cerra, M. G., Calabria, E., Bennardo, F., & Giudice, A. (2023). Effect of Implant Macro-Design and Magnetodynamic Surgical Preparation on Primary Implant Stability: An In Vitro Investigation. Dentistry Journal, 11(10), 227. https://doi.org/10.3390/dj11100227
Vancouver
Antonelli A, Barone S, Attanasio F, Salviati M, Cerra MG, Calabria E, et al. Effect of Implant Macro-Design and Magnetodynamic Surgical Preparation on Primary Implant Stability: An In Vitro Investigation. Dentistry Journal. 2023;11(10):227. doi:10.3390/dj11100227
BibTeX
@article{Antonelli2023,
author = {Antonelli, Alessandro and Barone, Selene and Attanasio, Ferdinando and Salviati, Marianna and Cerra, Maria Giulia and Calabria, Elena and Bennardo, Francesco and Giudice, Amerigo},
title = {Effect of Implant Macro-Design and Magnetodynamic Surgical Preparation on Primary Implant Stability: An In Vitro Investigation},
journal = {Dentistry Journal},
year = {2023},
volume = {11},
number = {10},
pages = {227},
doi = {10.3390/dj11100227}
}
EUVIMED