EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Primary stability and osseointegration comparing a novel tapered design tissue‐level implant with a parallel design tissue‐level implant. An experimental in vivo study

Thomas Gill iD, Sebastian Kühl iD, Simon Rawlinson, Benjamin Pippenger iD, Benjamin Bellon, Shakeel Shahdad iD

Clinical Oral Implants Research · 2024-09 · 35 (9) · 1114-1127

DOI: 10.1111/clr.14301 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 31.05.2024. Verfasst von Thomas Gill und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Dentistry, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK. Hauptthemen laut MEDLINE: Osseointegration, Dental Implants, Dental Implantation, Endosseous, Dental Prosthesis Design. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institut Straumann AG, Straumann Group.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of the present study was to compare a novel tapered, double‐threaded self‐tapping tissue‐Level design implant (TLC) to a well‐established parallel walled tissue‐level (TL) implant in terms of primary and secondary stability over time. Materials and Methods Test TLC ( n = 10/per timepoint) and control TL ( n = 10/per timepoint) implants were placed in the mandible of minipigs and left for submerged healing for 3, 6, and 12 weeks. Maximum insertion torque and implant stability quotient (ISQ) were measured for each implant at placement. Osseointegration and cortical bone maintenance were histologically evaluated by measuring total bone‐to‐implant contact (BIC) and first bone‐to‐implant contact (fBIC).

Results

A significantly higher maximum insertion torque was measured for the test implant TLC compared to the control TL implant (57.83 ± 24.73 Ncm and 22.62 ± 23.16 Ncm, respectively; p < .001). The mean ISQ values were comparable between the two implant types (75.00 ± 6.70 for TL compared to 75.40 ± 3.20 for TLC, p = .988). BIC was comparable between both implant types at each of the evaluated time points. The fBIC was found to be significantly more coronal at 12 weeks for the TLC implant compared to the TL implant (0.31 ± 0.83 mm for TLC compared to −0.22 ± 0.85 for TL, p = .027).

Conclusion

The novel tapered tissue level design implant showed improved primary stability and an overall improved crestal bone height maintenance compared to the parallel walled design at 12 weeks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsseointegrationDental ImplantsDental Implantation, EndosseousDental Prosthesis DesignSwine, MiniatureTorqueMandibleAnimalsSwineImplants, Experimental

Stichwörter der Autor:innen

implant crestal bone formationimplant geometryimplant surfaceosseointegrationtaperedtissue‐level

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Institute of Dentistry, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK.
  • Department of Oral Surgery, University Center for Dental Medicine, University of Basel, Basel, Switzerland.
  • Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Department of Preclinical Research, Institut Straumann AG, Basel, Switzerland.
  • Faculty of Medicine and Health Technology, University of Tampere, Tampere, Finland.
  • Department of Restorative Dentistry, the Royal London Dental Hospital, Barts Health NHS Trust, London, UK.

ORCID-Profile: Thomas Gill, Sebastian Kühl, Benjamin Pippenger, Shakeel Shahdad

Förderung

  • Institut Straumann AG
  • Straumann Group

Zitieren

APA

Gill, T., Kühl, S., Rawlinson, S., Pippenger, B., Bellon, B., & Shahdad, S. (2024). Primary stability and osseointegration comparing a novel tapered design tissue‐level implant with a parallel design tissue‐level implant. An experimental in vivo study. Clinical Oral Implants Research, 35(9), 1114-1127. https://doi.org/10.1111/clr.14301

Vancouver

Gill T, Kühl S, Rawlinson S, Pippenger B, Bellon B, Shahdad S. Primary stability and osseointegration comparing a novel tapered design tissue‐level implant with a parallel design tissue‐level implant. An experimental in vivo study. Clinical Oral Implants Research. 2024;35(9):1114-1127. doi:10.1111/clr.14301

BibTeX
@article{Gill2024,
  author = {Gill, Thomas and Kühl, Sebastian and Rawlinson, Simon and Pippenger, Benjamin and Bellon, Benjamin and Shahdad, Shakeel},
  title = {Primary stability and osseointegration comparing a novel tapered design tissue‐level implant with a parallel design tissue‐level implant. An experimental in vivo study},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  volume = {35},
  number = {9},
  pages = {1114--1127},
  doi = {10.1111/clr.14301}
}
Kostenlos starten →