Highly Sensitive Readout Interface for Real-Time Differential Precision Measurements with Impedance Biosensors
Biosensors · 2023
DOI: 10.3390/bios13010077 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Sara Neshani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Electrical and Computer Engineering Department, University of Alabama, Tuscaloosa, AL 35401, USA. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: United States Department of Agriculture, U.S. Department of Agriculture, University of Alabama.
Abstract (Originalsprache)
Field deployment is critical to developing numerous sensitive impedance transducers. Precise, cost-effective, and real-time readout units are being sought to interface these sensitive impedance transducers for various clinical or environmental applications. This paper presents a general readout method with a detailed design procedure for interfacing impedance transducers that generate small fractional changes in the impedance characteristics after detection. The emphasis of the design is obtaining a target response resolution considering the accuracy in real-time. An entire readout unit with amplification/filtering and real-time data acquisition and processing using a single microcontroller is proposed. Most important design parameters, such as the signal-to-noise ratio (SNR), common-mode-to-differential conversion, digitization configuration/speed, and the data processing method are discussed here. The studied process can be used as a general guideline to design custom readout units to interface with various developed transducers in the laboratory and verify the performance for field deployment and commercialization. A single frequency readout unit with a target 8-bit resolution to interface differentially placed transducers (e.g., bridge configuration) is designed and implemented. A single MCU is programmed for real-time data acquisition and sine fitting. The 8-bit resolution is achieved even at low SNR levels of roughly 7 dB by setting the component values and fitting algorithm parameters with the given methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Electrical and Computer Engineering Department, University of Alabama, Tuscaloosa, AL 35401, USA.
- Mechanical Engineering Department, University of Alabama, Tuscaloosa, AL 35401, USA.
- Electrical Engineering Department, Iowa State University, Ames, IA 50010, USA.
ORCID-Profile: Kasra Momeni
Förderung
- United States Department of Agriculture
- U.S. Department of Agriculture
- University of Alabama
Zitieren
APA
Neshani, S., Momeni, K., Chen, D. J., & Neihart, N. M. (2023). Highly Sensitive Readout Interface for Real-Time Differential Precision Measurements with Impedance Biosensors. Biosensors. https://doi.org/10.3390/bios13010077
Vancouver
Neshani S, Momeni K, Chen DJ, Neihart NM. Highly Sensitive Readout Interface for Real-Time Differential Precision Measurements with Impedance Biosensors. Biosensors. 2023. doi:10.3390/bios13010077
BibTeX
@article{Neshani2023,
author = {Neshani, Sara and Momeni, Kasra and Chen, Degang J and Neihart, Nathan M},
title = {Highly Sensitive Readout Interface for Real-Time Differential Precision Measurements with Impedance Biosensors},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13010077}
}
EUVIMED