Machine Learning-Based Image Reconstruction in Wearable CC-EIT of the Thorax: Robustness to Electrode Displacement
Sensors · 2025
DOI: 10.3390/s25216543 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Jan Jeschke und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland. Hauptthemen laut MEDLINE: Thorax, Machine Learning, Image Processing, Computer-Assisted, Wearable Electronic Devices. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The internal grant for employees of the Warsaw University of 463 Technology supporting scientific activity in the discipline of Biomedical Engineering.
Abstract (Originalsprache)
This study investigates the influence of variable electrode positions on image reconstruction in capacitively coupled electrical impedance tomography (CC-EIT) of the human thorax. Images were reconstructed by an adversarial neural network trained on a synthetic dataset generated using a tomographic model that included a wearable elastic band with 32 electrodes attached. Dataset generation was conducted using a previously developed numerical phantom of the thorax, combined with a newly developed algorithm for random selection of electrode positions based on physical limitations resulting from the elasticity of the band and possible position inaccuracies while putting the band on the patient’s chest. The thorax phantom included the heart, lungs, aorta, and spine. Four training and four testing datasets were generated using four different levels of electrode displacement. Reconstruction was conducted using four versions of neural networks trained on the datasets, with random ellipses included and noise added to achieve an SNR of 30 dB. The quality was assessed using pixel-to-pixel metrics such as the root-mean-square error, structural similarity index, 2D correlation coefficient, and peak signal-to-noise ratio. The results showed a strong negative influence of electrode displacement on reconstruction quality when no samples with displaced electrodes were present in the training dataset. Training the network on the dataset containing samples with electrode displacement allowed us to significantly improve the quality of the reconstructed images. Introducing samples with misplaced electrodes increased neural network robustness to electrode displacement while testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland.
ORCID-Profile: Jan Jeschke, Mikhail Ivanenko, Waldemar T Smolik, Damian Wanta, Mateusz Midura, Przemysław Wróblewski
Förderung
- The internal grant for employees of the Warsaw University of 463 Technology supporting scientific activity in the discipline of Biomedical Engineering
Zitieren
APA
Jeschke, J., Ivanenko, M., Smolik, W. T., Wanta, D., Midura, M., & Wróblewski, P. (2025). Machine Learning-Based Image Reconstruction in Wearable CC-EIT of the Thorax: Robustness to Electrode Displacement. Sensors. https://doi.org/10.3390/s25216543
Vancouver
Jeschke J, Ivanenko M, Smolik WT, Wanta D, Midura M, Wróblewski P. Machine Learning-Based Image Reconstruction in Wearable CC-EIT of the Thorax: Robustness to Electrode Displacement. Sensors. 2025. doi:10.3390/s25216543
BibTeX
@article{Jeschke2025,
author = {Jeschke, Jan and Ivanenko, Mikhail and Smolik, Waldemar T and Wanta, Damian and Midura, Mateusz and Wróblewski, Przemysław},
title = {Machine Learning-Based Image Reconstruction in Wearable CC-EIT of the Thorax: Robustness to Electrode Displacement},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25216543}
}
EUVIMED