Optimizing Microfluidic Impedance Cytometry by Bypass Electrode Layout Design
Biosensors · 2024
DOI: 10.3390/bios14040204 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Guangzu Wu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin 300161, China. Hauptthemen laut MEDLINE: Electrodes, Electric Impedance. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Microfluidic impedance cytometry (MIC) has emerged as a popular technique for single-cell analysis. Traditional MIC electrode designs consist of a pair of (or three) working electrodes, and their detection performance needs further improvements for microorganisms. In this study, we designed an 8-electrode MIC device in which the center pair was defined as the working electrode, and the connection status of bypass electrodes could be changed. This allowed us to compare the performance of layouts with no bypasses and those with floating or grounding electrodes by simulation and experiment. The results of detecting Φ 5 μm beads revealed that both the grounding and the floating electrode outperformed the no bypass electrode, and the grounding electrode demonstrated the best signal-to-noise ratio (SNR), coefficient of variation (CV), and detection sensitivity. Furthermore, the effects of different bypass grounding areas (numbers of grounding electrodes) were investigated. Finally, particles passing at high horizontal positions can be detected, and Φ 1 μm beads can be measured in a wide channel (150 μm) using a fully grounding electrode, with the sensitivity of bead volume detection reaching 0.00097%. This provides a general MIC electrode optimization technology for detecting smaller particles, even macromolecular proteins, viruses, and exosomes in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin 300161, China.
- National Bio-Protection Engineering Center, Tianjin 300161, China.
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China.
- School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin 300222, China.
ORCID-Profile: Xinwu Xie
Zitieren
APA
Wu, G., Zhang, Z., Du, M., Wu, D., Zhou, J., Hao, T., & Xie, X. (2024). Optimizing Microfluidic Impedance Cytometry by Bypass Electrode Layout Design. Biosensors. https://doi.org/10.3390/bios14040204
Vancouver
Wu G, Zhang Z, Du M, Wu D, Zhou J, Hao T, et al. Optimizing Microfluidic Impedance Cytometry by Bypass Electrode Layout Design. Biosensors. 2024. doi:10.3390/bios14040204
BibTeX
@article{Wu2024,
author = {Wu, Guangzu and Zhang, Zhiwei and Du, Manman and Wu, Dan and Zhou, Junting and Hao, Tianteng and Xie, Xinwu},
title = {Optimizing Microfluidic Impedance Cytometry by Bypass Electrode Layout Design},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14040204}
}
EUVIMED