A Multimodal Biomedical Sensing Approach for Muscle Activation Onset Detection
Sensors · 18.03.2026 · 26 (6) · 1907
DOI: 10.3390/s26061907 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 18.03.2026. Verfasst von Qiang Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Education and Military Affairs, China Jiliang University, Hangzhou 310018, China. Hauptthemen laut MEDLINE: Electromyography, Muscle, Skeletal, Biosensing Techniques. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Muscle onset detection is a fundamental problem in electromyography signal analysis, human–machine interaction, and rehabilitation assessment. In medical and biomedical applications, slow muscle activation onset processes are widely encountered in scenarios such as rehabilitation training, postural regulation, and fine motor control. Such processes are typically characterized by slowly varying amplitudes, long temporal durations, and high susceptibility to noise interference, which poses significant challenges for accurate identification of onset timing. To address these issues, a lightweight temporal attention method for slow muscle activation onset detection is proposed and systematically validated under multimodal experimental settings. The proposed method takes surface electromyography signals as the primary input, while synchronously acquired optical motion image data are incorporated into the experimental design and result analysis, thereby aligning with the common joint use of optical imaging and physiological signals in medical and biomedical research. From a methodological perspective, the proposed framework is composed of lightweight temporal feature encoding, a slow activation-aware temporal attention mechanism, and noise suppression with stable decision strategies. Under the constraint of low computational complexity, the ability to model progressive activation signals is effectively enhanced. Experiments are conducted on a dataset containing multiple types of slow activation movements, and model performance is evaluated using five-fold cross-validation. The results demonstrate that under regular signal-to-noise ratio conditions, the proposed method significantly outperforms traditional threshold-based approaches, classical machine learning models, and several deep learning baselines in terms of onset detection accuracy, recall, and precision. Specifically, onset detection accuracy reaches approximately 92%, recall is around 90%, and precision is approximately 93%. Meanwhile, the average onset detection error and detection delay are reduced to about 41ms and 28ms, respectively, with the false positive rate controlled at approximately 2.2%. Stable performance is further maintained under different noise levels and cross-subject settings, indicating strong robustness and generalization capability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Education and Military Affairs, China Jiliang University, Hangzhou 310018, China.
- National School of Development, Peking University, Beijing 100871, China.
- China Agricultural University, Beijing 100083, China.
- Artificial Intelligence Research Institute, Tsinghua University, Beijing 100084, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Chen, Q., Li, H., Xiang, Z., Lin, M., Yi, Y., Tang, H., & Zhan, Y. (2026). A Multimodal Biomedical Sensing Approach for Muscle Activation Onset Detection. Sensors, 26(6), 1907. https://doi.org/10.3390/s26061907
Vancouver
Chen Q, Li H, Xiang Z, Lin M, Yi Y, Tang H, et al. A Multimodal Biomedical Sensing Approach for Muscle Activation Onset Detection. Sensors. 2026;26(6):1907. doi:10.3390/s26061907
BibTeX
@article{Chen2026,
author = {Chen, Qiang and Li, Haofei and Xiang, Zhe and Lin, Moxian and Yi, Yinfei and Tang, Haoran and Zhan, Yan},
title = {A Multimodal Biomedical Sensing Approach for Muscle Activation Onset Detection},
journal = {Sensors},
year = {2026},
volume = {26},
number = {6},
pages = {1907},
doi = {10.3390/s26061907}
}
EUVIMED