An optimized filter design approach for enhancing imaging quality in industrial linear accelerator
Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 2024
DOI: 10.3233/xst-240032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2024. Verfasst von Gang Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Particle Accelerators, Tomography, X-Ray Computed, Equipment Design. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The polychromatic X-rays generated by a linear accelerator (Linac) often result in noticeable hardening artifacts in images, posing a significant challenge to accurate defect identification. To address this issue, a simple yet effective approach is to introduce filters at the radiation source outlet. However, current methods are often empirical, lacking scientifically sound metrics. OBJECTIVE: This study introduces an innovative filter design method that optimizes filter performance by balancing the impact of ray intensity and energy on image quality. MATERIALS AND METHODS: Firstly, different spectra under various materials and thicknesses of filters were obtained using GEometry ANd Tracking (Geant4) simulation. Subsequently, these spectra and their corresponding incident photon counts were used as input sources to generate different reconstructed images. By comprehensively comparing the intensity differences and noise in images of defective and non-defective regions, along with considering hardening indicators, the optimal filter was determined. RESULTS: The optimized filter was applied to a Linac-based X-ray computed tomography (CT) detection system designed for identifying defects in graphite materials within high-temperature gas-cooled reactor (HTR), with defect dimensions of 2 mm. After adding the filter, the hardening effect reduced by 22%, and the Defect Contrast Index (DCI) reached 3.226. CONCLUSION: The filter designed based on the parameters of Average Difference (AD) and Defect Contrast Index (DCI) can effectively improve the quality of defect images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, China.
- Beijing Key Laboratory of Nuclear Detection & Measurement Technology, Beijing, China.
Zitieren
APA
Chen, G., Zhang, Z., Xu, S., Jiang, S., Liu, X., Tang, P., Li, S., & Xiang, X. (2024). An optimized filter design approach for enhancing imaging quality in industrial linear accelerator. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-240032
Vancouver
Chen G, Zhang Z, Xu S, Jiang S, Liu X, Tang P, et al. An optimized filter design approach for enhancing imaging quality in industrial linear accelerator. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2024. doi:10.3233/xst-240032
BibTeX
@article{Chen2024,
author = {Chen, Gang and Zhang, Zehuan and Xu, Shuo and Jiang, Shibo and Liu, Ximing and Tang, Peng and Li, Songyuan and Xiang, Xincheng},
title = {An optimized filter design approach for enhancing imaging quality in industrial linear accelerator},
journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
year = {2024},
doi = {10.3233/xst-240032}
}
EUVIMED