Performance evaluation of a flexible GAGG sheet for surface imaging of x-rays from computed tomography (CT) and linear accelerator (LINAC)
Biomedical Physics & Engineering Express · 2026
DOI: 10.1088/2057-1976/ae451e ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, 2026. Verfasst von Seiichi Yamamoto und 10 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Science and Engineering, Waseda University, Japan. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Particle Accelerators, Gadolinium. Die Arbeit nennt 18 Literaturangaben. Gefördert von: JST ERATO.
Abstract (Originalsprache)
A flexible scintillator sheet made of Ce-doped Gd 3 Al 2 Ga 3 O 12 (GAGG) powder mixed with a two-part silicone adhesive enabled high-intensity imaging of proton beams on complex surfaces; however, its effectiveness for x-ray imaging remained unclear. To investigate this, we tested surface imaging with the GAGG sheet for both x-rays from computed tomography (CT) system and high-energy x-rays from linear accelerator (LINAC). For imaging of x-ray beam from CT system, we irradiated a flexible GAGG sheet with 140 kV x-rays, positioning it on a patient bed or curved surface of a cylindrical phantom. The resulting light emission on the GAGG sheet was captured by a CMOS camera. For LINAC x-ray imaging, we irradiated the GAGG sheet with 6 MV x-rays, setting it on a flat phantom or a human head phantom, and again captured the emitted light using a CMOS camera. In both CT and LINAC x-ray imaging, the light produced on the GAGG sheet was successfully captured at intervals as short as 100 ms, enabling real-time tracking of beams. The light output from CT x-rays was more than 50 times higher than that of plastic scintillator, while the light output from LINAC x-rays was 1.2 times higher. Given its adaptability to complex surfaces and high light emission for x-rays as well as real-time imaging capability, the flexible GAGG sheet shows potential for efficient surface beam imaging in both CT and LINAC x-ray applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Science and Engineering, Waseda University, Japan.
- Nagoya University Graduate School of Medicine, Japan.
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan.
- New Industry Creation Hatchery Center (NICHe), Tohoku University, Japan.
- Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, The University of Osaka, Japan.
ORCID-Profile: Seiichi Yamamoto, Katsunori Yogo
Förderung
- JST ERATO
Zitieren
APA
Yamamoto, S., Nakanishi, K., Yogo, K., Noguchi, Y., Okudaira, K., Nakaya, T., Yoshino, M., Kamada, K., Yoshikawa, A., Nishio, T., & Kataoka, J. (2026). Performance evaluation of a flexible GAGG sheet for surface imaging of x-rays from computed tomography (CT) and linear accelerator (LINAC). Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/ae451e
Vancouver
Yamamoto S, Nakanishi K, Yogo K, Noguchi Y, Okudaira K, Nakaya T, et al. Performance evaluation of a flexible GAGG sheet for surface imaging of x-rays from computed tomography (CT) and linear accelerator (LINAC). Biomedical Physics & Engineering Express. 2026. doi:10.1088/2057-1976/ae451e
BibTeX
@article{Yamamoto2026,
author = {Yamamoto, Seiichi and Nakanishi, Kohei and Yogo, Katsunori and Noguchi, Yumiko and Okudaira, Kuniyasu and Nakaya, Takayoshi and Yoshino, Masao and Kamada, Kei and Yoshikawa, Akira and Nishio, Teiji and Kataoka, Jun},
title = {Performance evaluation of a flexible GAGG sheet for surface imaging of x-rays from computed tomography (CT) and linear accelerator (LINAC)},
journal = {Biomedical Physics & Engineering Express},
year = {2026},
doi = {10.1088/2057-1976/ae451e}
}
EUVIMED