EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Clinical implementation and evaluation of a patient‐specific surface‐guided clearance mapping system for collision avoidance and noncoplanar beam planning

Siqiu Wang iD, Eric Chambers, Ruiqi Li iD, Yesenia Gonzalez, Xinran Zhong iD, Zohaib Iqbal, Kara James, Jennifer Cleaton, David Sher, Andrew Godley, David Parsons iD

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70548 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Siqiu Wang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Breast Neoplasms, Lung Neoplasms, Phantoms, Imaging. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose/objectives Collision avoidance is critical in external beam radiotherapy to ensure patient safety and plan deliverability. Limited understanding of the collision‐free treatment space risks both patient safety and unnecessary exclusion of useful beams—particularly in noncoplanar setups—resulting in suboptimal plans. Conventional methods (manual clearance checks or CT‐based assessments, etc.) are either labor‐intensive or fail to account for collision‐prone anatomy outside the scan. We investigated and clinically implemented a virtual patient‐specific clearance mapping system and evaluated its utility as a noncoplanar beam selection tool to improve plan quality. Materials/methods The system integrates full‐body, patient‐specific surfaces—acquired during simulation using near‐infrared imaging—with interactive 3D linac/couch models. Clearance mapping accuracy was validated through phantom measurements and a comparative analysis with manual clearance checks of 60 patients across treatment sites. Workflow efficiency data were reported over three years of clinical implementation. A workflow for patient‐specific non coplanar beam selection was proposed and evaluated in 20 lung stereotactic body radiation therapy (SBRT) and 18 breast stereotactic partial breast irradiation (sPBI) cases.

Results

The clearance mapping accuracy was within ± 1° (gantry/couch rotation) of phantom measurements. For 60 patients, the virtual predictions accurately identified all potential clearance issues, while manual verification missed 5 collision events. Virtual checks saved approximately 15 min of linac and therapist time per plan and eliminated an average 6.2‐clinical hour planning delay. With the proposed beam selection workflow, noncoplanar replans for lung SBRT improved target conformality (Paddick Conformity Index from 0.89 to 0.91, p < 0.01) and reduced low dose spillage. For breast sPBI, heart mean dose was lowered (103 cGy to 68 cGy, p < 0.01). Delivery time increased by approx. 30s per plan.

Conclusions

The virtual clearance mapping system outperformed manual verification, streamlined clinical workflow, and could significantly improve plan quality through efficient noncoplanar beam selection. It has replaced manual verification at our institution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedBreast NeoplasmsLung NeoplasmsPhantoms, ImagingRadiosurgeryHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedOrgans at RiskFemaleParticle AcceleratorsTomography, X-Ray ComputedImage Processing, Computer-Assisted

Stichwörter der Autor:innen

clearance mappingnoncoplanar treatmentpatient safetysurface‐guided radiotherapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.

ORCID-Profile: Siqiu Wang, Ruiqi Li, Xinran Zhong, David Parsons

Zitieren

APA

Wang, S., Chambers, E., Li, R., Gonzalez, Y., Zhong, X., Iqbal, Z., James, K., Cleaton, J., Sher, D., Godley, A., & Parsons, D. (2026). Clinical implementation and evaluation of a patient‐specific surface‐guided clearance mapping system for collision avoidance and noncoplanar beam planning. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70548

Vancouver

Wang S, Chambers E, Li R, Gonzalez Y, Zhong X, Iqbal Z, et al. Clinical implementation and evaluation of a patient‐specific surface‐guided clearance mapping system for collision avoidance and noncoplanar beam planning. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70548

BibTeX
@article{Wang2026,
  author = {Wang, Siqiu and Chambers, Eric and Li, Ruiqi and Gonzalez, Yesenia and Zhong, Xinran and Iqbal, Zohaib and James, Kara and Cleaton, Jennifer and Sher, David and Godley, Andrew and Parsons, David},
  title = {Clinical implementation and evaluation of a patient‐specific surface‐guided clearance mapping system for collision avoidance and noncoplanar beam planning},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70548}
}
Kostenlos starten →