Clinical Evaluation of Deep Learning–Reconstructed Postcontrast 3D T1-Weighted Volume Interpolated Breath-Hold Examination (VIBE) Compared with Standard VIBE for Detection of Internal Auditory Canal Lesions
American Journal of Neuroradiology · 2026
DOI: 10.3174/ajnr.a9189 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift American Journal of Neuroradiology, 2026. Verfasst von Chen-Hua Chiang und 10 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Radiology (C.-H.C., S.B., A.H., A.T., J.C., S.Y.H.), Massachusetts General Hospital, Harvard Medical School, Boston, Massachus…. Hauptthemen laut MEDLINE: Deep Learning, Imaging, Three-Dimensional, Breath Holding, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Siemens Healthineers and the National Institutes of Health.
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: Contrast-enhanced volume interpolated breath-hold examination (VIBE) is commonly used for evaluating internal auditory canal (IAC) pathology. Deep learning (DL)-reconstruction has been shown to reduce scan time while maintaining diagnostic quality. Our purpose was to compare the image quality of a DL-reconstructed post-contrast-enhanced VIBE sequence with standard 3D VIBE in a clinical setting. MATERIALS AND METHODS: This study included 74 patients undergoing contrast-enhanced MRI for the assessment of IAC pathology. The participants were scanned with a standard 3D VIBE sequence and DL-reconstructed VIBE (DL-VIBE) sequences. Two neuroradiologists performed a head-to-head evaluation of both sequences in terms of image-quality metrics, identification of key anatomic structures, and pathologic enhancement when present. A third neuroradiologist adjudicated the discrepant results. Superiority testing was performed to compare DL-VIBE with standard VIBE in image quality metrics, and a noninferiority test with a 15% margin was performed to test the visibility of key anatomic structures and pathologic enhancing lesions. Interrater agreement and quantitative assessment of an image-wise SNR, contrast-noise ratio, IAC-specific SNR, and tumor volumetric measurements as applicable were performed. RESULTS: DL-VIBE enabled approximately 25% scan time reduction (from 3 minutes 2 seconds on the standard sequence to 2 minutes 17 seconds on the DL sequence). DL-VIBE was superior to standard VIBE for all image-quality metrics (P < .01). DL-VIBE was noninferior to standard VIBE for structural visibility of key structures (P < .001) and was noninferior for pooled pathologic enhancement (P = .049). Interrater agreements were moderate to almost perfect across all categories (κ = 0.515-1). DL-VIBE provided significantly higher mean image-wise SNR (71.8 [SD, 23.2] versus 39.4 [SD, 10.7], respectively; P < .001), while providing comparable lesion conspicuity and volumetric assessment. CONCLUSIONS: DL-VIBE is a strong alternative to standard 3D VIBE for clinical IAC assessment, providing superior image quality and comparable visibility of key anatomic structures and enhancing pathology while offering higher image SNR with 25% reduced scan time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- From the Department of Radiology (C.-H.C., S.B., A.H., A.T., J.C., S.Y.H.), Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts.
- Department of Medical Imaging (C.-H.C.), Taipei Medical University-Shuang Ho Hospital, New Taipei City, Taiwan.
- Department of Radiology (C.-H.C.), School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.
- Department of Radiology (S.B.), Siriraj Hospital, Mahidol University, Bangkok, Thailand.
- Siemens Medical Solutions USA (W.-C.L., B.C., R.S., S.F.C.), Boston, Massachusetts.
- Siemens Healthineers AG (D.N.), Erlangen, Germany.
ORCID-Profile: Chen-Hua Chiang, Azadeh Hajati, Wei-Ching Lo, Dominik Nickel, Bryan Clifford, Susie Y Huang
Förderung
- Siemens Healthineers and the National Institutes of Health
Zitieren
APA
Chiang, C. H., Buathong, S., Hajati, A., Tabari, A., Lo, W. C., Nickel, D., Clifford, B., Sellers, R., Cauley, S. F., Conklin, J., & Huang, S. Y. (2026). Clinical Evaluation of Deep Learning–Reconstructed Postcontrast 3D T1-Weighted Volume Interpolated Breath-Hold Examination (VIBE) Compared with Standard VIBE for Detection of Internal Auditory Canal Lesions. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a9189
Vancouver
Chiang CH, Buathong S, Hajati A, Tabari A, Lo WC, Nickel D, et al. Clinical Evaluation of Deep Learning–Reconstructed Postcontrast 3D T1-Weighted Volume Interpolated Breath-Hold Examination (VIBE) Compared with Standard VIBE for Detection of Internal Auditory Canal Lesions. American Journal of Neuroradiology. 2026. doi:10.3174/ajnr.a9189
BibTeX
@article{Chiang2026,
author = {Chiang, Chen-Hua and Buathong, Sittaya and Hajati, Azadeh and Tabari, Azadeh and Lo, Wei-Ching and Nickel, Dominik and Clifford, Bryan and Sellers, Robert and Cauley, Stephen F and Conklin, John and Huang, Susie Y},
title = {Clinical Evaluation of Deep Learning–Reconstructed Postcontrast 3D T1-Weighted Volume Interpolated Breath-Hold Examination (VIBE) Compared with Standard VIBE for Detection of Internal Auditory Canal Lesions},
journal = {American Journal of Neuroradiology},
year = {2026},
doi = {10.3174/ajnr.a9189}
}