EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Temporal Bone Anatomy at 0.55 T: Comparison to 1.5/3T MR and High-Resolution CT

Radhika Rajeev, Lauren J Kelsey, Nicole Seiberlich, Ashok Srinivasan, Mohannad Ibrahim, Eric Liao, Maria Masotti, Chamila Perera, Vikas Gulani, Jayapalli Bapuraj, Shruti Mishra

Academic Radiology · 2025

DOI: 10.1016/j.acra.2025.08.034 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Academic Radiology, 2025. Verfasst von Radhika Rajeev und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan, Ann Arbor, MI (R.R., L.J.K., N.S., A.S., M.I., E.L., V.G., J.B., S.M.). Electronic address: drradhik…. Hauptthemen laut MEDLINE: Temporal Bone, Tomography, X-Ray Computed, Magnetic Resonance Imaging. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: The purpose of this study is to evaluate whether the whole-body 0.55 T MRI may be a clinically acceptable or non-inferior alternative to 1.5T/3T for internal auditory canal (IAC) imaging due to greater field homogeneity and resultant reduced susceptibility artifacts near air-bone interfaces. We compare image quality, visibility of IAC anatomy, and cochlear measurements at 0.55 T vs. 1.5T/3T. MATERIALS AND METHODS: In this IRB-approved retrospective study, 25 patients who underwent 0.55 T MRI using IAC protocol with prior/ subsequent comparative scans at 1.5T/3T scans were selected. A subset (n=13) also had high-resolution CT (HRCT). 3 board-certified neuroradiologists independently scored the visibility of anatomical structures and overall image quality on a 4-point Likert scale in one non-pathological ear. Readers also measured cochlear length, cochlear width, and IAC width on double oblique coronal images. RESULTS: All three readers rated the visualization of anatomic structures as clinically acceptable (scores ≥ 2) at 0.55 T. Two of the three readers reported no significant difference in visualization of these structures between 0.55 T and higher field strengths. Quantitative measurements (cochlear length, width, and IAC width) at 0.55 T were comparable to 1.5T/3T. One reader (R2) rated overall image quality significantly lower at 0.55 T (mean score: 3.1 at 0.55 T vs. 2.6 at HF; p = 0.005). CONCLUSION: Clinical evaluation of IAC and inner ear structures using a 3D T2w SPACE sequence at 0.55 T is an acceptable alternative to imaging at conventional field strengths of 1.5/3T.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Temporal BoneTomography, X-Ray ComputedMagnetic Resonance ImagingHumansFemaleMaleMiddle AgedAdultRetrospective StudiesAgedReproducibility of ResultsSensitivity and SpecificityEar, InnerImage Enhancement

Stichwörter der Autor:innen

0.55 T MRIInner Ear ImagingInternal Auditory Canal

Autor:innen und Institutionen

  • Department of Radiology, University of Michigan, Ann Arbor, MI (R.R., L.J.K., N.S., A.S., M.I., E.L., V.G., J.B., S.M.). Electronic address: drradhikarajeev9@gmail.com.
  • Department of Radiology, University of Michigan, Ann Arbor, MI (R.R., L.J.K., N.S., A.S., M.I., E.L., V.G., J.B., S.M.). Electronic address: laurkels@umich.edu.
  • Department of Radiology, University of Michigan, Ann Arbor, MI (R.R., L.J.K., N.S., A.S., M.I., E.L., V.G., J.B., S.M.). Electronic address: nse@med.umich.edu.
  • Department of Radiology, University of Michigan, Ann Arbor, MI (R.R., L.J.K., N.S., A.S., M.I., E.L., V.G., J.B., S.M.). Electronic address: ashoks@med.umich.edu.
  • Department of Radiology, University of Michigan, Ann Arbor, MI (R.R., L.J.K., N.S., A.S., M.I., E.L., V.G., J.B., S.M.). Electronic address: mibrahim@med.umich.edu.
  • Department of Radiology, University of Michigan, Ann Arbor, MI (R.R., L.J.K., N.S., A.S., M.I., E.L., V.G., J.B., S.M.). Electronic address: ealiao@med.umich.edu.

Zitieren

APA

Rajeev, R., Kelsey, L. J., Seiberlich, N., Srinivasan, A., Ibrahim, M., Liao, E., Masotti, M., Perera, C., Gulani, V., Bapuraj, J., & Mishra, S. (2025). Temporal Bone Anatomy at 0.55 T: Comparison to 1.5/3T MR and High-Resolution CT. Academic Radiology. https://doi.org/10.1016/j.acra.2025.08.034

Vancouver

Rajeev R, Kelsey LJ, Seiberlich N, Srinivasan A, Ibrahim M, Liao E, et al. Temporal Bone Anatomy at 0.55 T: Comparison to 1.5/3T MR and High-Resolution CT. Academic Radiology. 2025. doi:10.1016/j.acra.2025.08.034

BibTeX
@article{Rajeev2025,
  author = {Rajeev, Radhika and Kelsey, Lauren J and Seiberlich, Nicole and Srinivasan, Ashok and Ibrahim, Mohannad and Liao, Eric and Masotti, Maria and Perera, Chamila and Gulani, Vikas and Bapuraj, Jayapalli and Mishra, Shruti},
  title = {Temporal Bone Anatomy at 0.55 T: Comparison to 1.5/3T MR and High-Resolution CT},
  journal = {Academic Radiology},
  year = {2025},
  doi = {10.1016/j.acra.2025.08.034}
}
Kostenlos starten →