Impact of Ultrahigh Sensitivity and Continuous Bed Motion on Performance Characteristics of Biograph Vision Quadra PET/CT

Mostafa Roya, Charalampos Tsoumpas, Johannes H van Snick, Viet Dao, Antoon T M Willemsen, Riemer H J A Slart, Ronald Boellaard, Andor W J M Glaudemans, Joyce van Sluis

Journal of Nuclear Medicine · 2025-10 · 66 (10) · 1659-1665

DOI: 10.2967/jnumed.125.270078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine, online erschienen am 28.08.2025. Verfasst von Mostafa Roya und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Motion, Beds. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous bed motion (CBM) for long-axial-field-of-view PET/CT enables swift total-body examination of patients. However, the sensitivity profile along the axial field of view (AFOV) varies significantly, and its effect on image quality when combined with CBM remains unexplored. This study assesses the effects of ultrahigh sensitivity (UHS) and CBM on recovery coefficients (RCs) and spatial resolution (SR).

Methods

Phantom measurements, performed in static bed and CBM acquisition with different bed speeds (3.5, 7, 14, and 30 mm/s), were reconstructed for both high-sensitivity (HS) and UHS modes, and their quality was assessed using the RC and full width at half maximum of the point-spread function. In addition, 7 clinically referred oncologic patients underwent a combined CBM and UHS [18F]FDG PET/CT scan. Metrics derived from lesions and healthy tissues were compared across acquisition modes.

Results

Mean RC was lower in both UHS ( 0.94) and lesions (r 2 > 0.99) showed excellent correlation. The coefficient of variation was significantly different for the liver.

Conclusion

Elaborate protocols using UHS and CBM could be a step toward swift total-body PET care with only a marginal increase in noise. CBM allows a larger part of the body to be examined and helps to mitigate substantial sensitivity differences along the AFOV, albeit at the cost of slightly lower RC.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyMotionBedsHumansPhantoms, ImagingImage Processing, Computer-AssistedMaleFemaleMovementMiddle AgedFluorodeoxyglucose F18Aged

Stichwörter der Autor:innen

continuous bed motionrecovery coefficientspatial resolutiontotal-body PETultrahigh sensitivity

Substanzen

Fluorodeoxyglucose F18

Autor:innen und Institutionen

  • Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands; c.tsoumpas@umcg.nl.
  • Department of Statistics, School of Mathematics, University of Leeds, Leeds, United Kingdom.
  • Biomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands; and.
  • Department of Radiology and Nuclear Medicine, Amsterdam UMC, location VUMC, Amsterdam, The Netherlands.

Zitieren

APA

Roya, M., Tsoumpas, C., van Snick, J. H., Dao, V., Willemsen, A. T. M., Slart, R. H. J. A., Boellaard, R., Glaudemans, A. W. J. M., & van Sluis, J. (2025). Impact of Ultrahigh Sensitivity and Continuous Bed Motion on Performance Characteristics of Biograph Vision Quadra PET/CT. Journal of Nuclear Medicine, 66(10), 1659-1665. https://doi.org/10.2967/jnumed.125.270078

Vancouver

Roya M, Tsoumpas C, van Snick JH, Dao V, Willemsen ATM, Slart RHJA, et al. Impact of Ultrahigh Sensitivity and Continuous Bed Motion on Performance Characteristics of Biograph Vision Quadra PET/CT. Journal of Nuclear Medicine. 2025;66(10):1659-1665. doi:10.2967/jnumed.125.270078

BibTeX
@article{Roya2025,
  author = {Roya, Mostafa and Tsoumpas, Charalampos and van Snick, Johannes H and Dao, Viet and Willemsen, Antoon T M and Slart, Riemer H J A and Boellaard, Ronald and Glaudemans, Andor W J M and van Sluis, Joyce},
  title = {Impact of Ultrahigh Sensitivity and Continuous Bed Motion on Performance Characteristics of Biograph Vision Quadra PET/CT},
  journal = {Journal of Nuclear Medicine},
  year = {2025},
  volume = {66},
  number = {10},
  pages = {1659--1665},
  doi = {10.2967/jnumed.125.270078}
}
Kostenlos starten →