The Utility of a Modified Data-Driven Motion Correction Method Incorporating Computed Tomography Positional Data for Positron Emission Tomography
The Tohoku Journal of Experimental Medicine · 2025
DOI: 10.1620/tjem.2025.j072 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Tohoku Journal of Experimental Medicine, 2025. Verfasst von Hayato Odagiri und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Motion, Image Processing, Computer-Assisted, Positron-Emission Tomography.
Abstract (Originalsprache)
In positron emission tomography/computed tomography (PET/CT), long image acquisition time often causes patient motion and misalignment between the PET and CT images. This misalignment can compromise the accuracy of attenuation correction and quantitative values, thus affecting diagnostic reliability. Recently, data-driven motion correction (DDMC) methods have been developed to detect motion using brief static PET images, and our previous study also demonstrated the effectiveness of the DDMC method. However, DDMC assumes alignment between PET reference images and CT scans used for attenuation correction. When patients move after CT scan, the PET and CT images misalign, necessitating rescanning or manual realignment. The present study introduces a modified approach, namely DDMC+CT, that integrates CT positional data into the DDMC process to address PET/CT misalignment. We evaluated the DDMC+CT approach using a phantom study and clinical images. The phantom study simulated PET/CT misalignment by moving a Hoffman phantom post-CT scan, with contrast and standardized uptake values (SUV) compared with and without DDMC+CT. The clinical images included whole-body PET/CT scans with head and neck motion, where quantitative and visual assessments were performed. The DDMC+CT method successfully corrected PET/CT misalignment in phantom and clinical images, yielding SUV and contrast values consistent with reference images, resulting in improved diagnostic accuracy. The DDMC+CT method demonstrates a potential for clinical application, where it may minimize rescans and reduce patient and operator burden by allowing automatic misalignment correction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine.
- Department of Diagnostic Radiology, Tohoku University Hospital.
- Division of Radiation Protection and Safety Control, Cyclotron and Radioisotope Center, Tohoku University.
- GE HealthCare.
- Department of Radiological Technology, Tohoku University Hospital.
Zitieren
APA
Odagiri, H., Watabe, H., Takanami, K., Yamaguchi, N., Kawakami, H., Katsuki, A., Tanaka, Y., Takeuchi, T., Kodama, H., Usui, A., Takase, K., & Kaneta, T. (2025). The Utility of a Modified Data-Driven Motion Correction Method Incorporating Computed Tomography Positional Data for Positron Emission Tomography. The Tohoku Journal of Experimental Medicine. https://doi.org/10.1620/tjem.2025.j072
Vancouver
Odagiri H, Watabe H, Takanami K, Yamaguchi N, Kawakami H, Katsuki A, et al. The Utility of a Modified Data-Driven Motion Correction Method Incorporating Computed Tomography Positional Data for Positron Emission Tomography. The Tohoku Journal of Experimental Medicine. 2025. doi:10.1620/tjem.2025.j072
BibTeX
@article{Odagiri2025,
author = {Odagiri, Hayato and Watabe, Hiroshi and Takanami, Kentaro and Yamaguchi, Nao and Kawakami, Hirofumi and Katsuki, Akie and Tanaka, Yoshitaka and Takeuchi, Takashi and Kodama, Hiroyasu and Usui, Akihito and Takase, Kei and Kaneta, Tomohiro},
title = {The Utility of a Modified Data-Driven Motion Correction Method Incorporating Computed Tomography Positional Data for Positron Emission Tomography},
journal = {The Tohoku Journal of Experimental Medicine},
year = {2025},
doi = {10.1620/tjem.2025.j072}
}