Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 20.05.2025. Verfasst von Jonathan Stelter und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich…. Hauptthemen laut MEDLINE: Respiration, Liver, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, TUM International Graduate School of Science and Engineering, Philips Healthcare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a self‐navigation approach to estimate respiratory motion for motion‐corrected liver mapping using a Look‐Locker acquisition with radial stack‐of‐stars trajectory.

Methods

The proposed method derives 1D field‐map profiles from the oversampled k‐space center to estimate a normalized breathing curve and the variation amplitude for each slice and coil. drift and contrast variations, inherent to the Look‐Locker acquisition, were modeled and corrected by fitting and demodulating drift and offset terms. The breathing curve was employed to bin data into motion states for motion‐resolved reconstruction, followed by water‐specific mapping. Simulations with an anatomical body model and in vivo experiments with a Look‐Locker multi‐echo gradient echo sequence were performed to validate the technique. The estimated normalized breathing curve was compared with magnitude‐ and phase‐based self‐navigation approaches using principal component analysis.

Results

The proposed self‐navigation reliably estimated the normalized breathing curve and the variation amplitude in simulations and in vivo. variation amplitudes increased with greater tissue displacement, with median values across slices and coils ranging from 4 to 15 Hz at 3 T in volunteers. Motion‐resolved reconstruction using the estimated breathing curve reduced motion artifacts and improved image and mapping quality compared to motion‐averaged reconstruction. Conclusion self‐navigation allows estimation of respiratory motion in acquisitions with varying contrast and quantifies the variation amplitude, providing a possible surrogate signal for tissue displacement and enabling self‐gated liver mapping using a Look‐Locker approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RespirationLiverMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansAlgorithmsMotionComputer SimulationPhantoms, ImagingMovementMaleAdultArtifacts

Stichwörter der Autor:innen

free‐breathinggradient echo imagingself‐navigationwater‐fat separation

Autor:innen und Institutionen

  • Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
  • Philips GmbH Market DACH, Hamburg, Germany.
  • Institute of Machine Learning for Biomedical Imaging, Helmholtz Munich, Neuherberg, Germany.
  • School of Computation, Information and Technology, Technical University of Munich, Munich, Germany.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany.

ORCID-Profile: Jonathan Stelter

Förderung

  • Deutsche Forschungsgemeinschaft
  • TUM International Graduate School of Science and Engineering
  • Philips Healthcare
  • International Graduate School of Science and Engineering
  • Philips

Zitieren

APA

Stelter, J., Weiss, K., Spieker, V., Schnabel, J. A., Braren, R. F., & Karampinos, D. C. (2025). B 0 navigator enables respiratory motion navigation in radial stack‐of‐stars liver Look‐Locker T 1 mapping. Magnetic Resonance in Medicine, 94(4), 1458-1468. https://doi.org/10.1002/mrm.30567

Vancouver

Stelter J, Weiss K, Spieker V, Schnabel JA, Braren RF, Karampinos DC. B 0 navigator enables respiratory motion navigation in radial stack‐of‐stars liver Look‐Locker T 1 mapping. Magnetic Resonance in Medicine. 2025;94(4):1458-1468. doi:10.1002/mrm.30567

BibTeX
@article{Stelter2025,
  author = {Stelter, Jonathan and Weiss, Kilian and Spieker, Veronika and Schnabel, Julia A and Braren, Rickmer F and Karampinos, Dimitrios C},
  title = {B 0 navigator enables respiratory motion navigation in radial stack‐of‐stars liver Look‐Locker T 1 mapping},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  volume = {94},
  number = {4},
  pages = {1458--1468},
  doi = {10.1002/mrm.30567}
}