Motion-robust proton density fat fraction and $${T_2}^*$$ mapping in supraclavicular adipose tissue using radial stack-of-stars imaging
Magnetic Resonance Materials in Physics, Biology and Medicine · 2025
DOI: 10.1007/s10334-025-01302-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von Johannes Raspe und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich (TUM), …. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Adipose Tissue, Brown, Image Processing, Computer-Assisted, Adipose Tissue. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Technische Universität München.
Abstract (Originalsprache)
Purpose
Accurate quantification of proton density fat fraction (PDFF) and $${T_2}^*$$ T 2 ∗ in the supracalvicular (SCV) fossa is critical for studying brown adipose tissue (BAT), but is challenged by respiratory motion-induced $$B_0$$ B 0 fluctuations. This study compares conventional Cartesian imaging to a radial stack-of-stars (SoS) trajectory, with and without retrospective temporal $$B_0$$ B 0 correction, in terms of PDFF and $${T_2}^*$$ T 2 ∗ mapping precision.
Methods
Motion-induced $$B_0$$ B 0 fluctuations and tissue displacement were modeled using a digital anatomical phantom. Both Cartesian and radial SoS trajectories were simulated, with temporal $$B_0$$ B 0 correction, relying on oversampling of the k -space center, applied to the radial SoS data. Additionally, repeated in vivo scans were performed in four volunteers using both trajectories. PDFF and $${T_2}^*$$ T 2 ∗ were quantified across repetitions.
Results
Simulations demonstrated smaller PDFF and $${T_2}^*$$ T 2 ∗ errors in radial SoS compared to Cartesian imaging under the influence of simulated motion effects. In the simulations, the mean absolute PDFF error decreased from $${1.07\,\mathrm{\%}}_\textrm{PDFF}$$ 1.07 % PDFF with Cartesian to $${0.47\,\mathrm{\%}}_\textrm{PDFF}$$ 0.47 % PDFF with radial SoS, and the $${T_2}^*$$ T 2 ∗ error decreased from 7.50 ms to 3.37 ms. In vivo, radial SoS provided higher repeatability for both parameters compared to Cartesian acquisitions, as measured by the inter-scan coefficient of variation. Retrospective temporal $$B_0$$ B 0 correction further improved the repeatability of $${T_2}^*$$ T 2 ∗ quantification.
Conclusions
Radial SoS imaging improves motion robustness and repeatability of PDFF and $${T_2}^*$$ T 2 ∗ quantification in the SCV fossa compared to Cartesian acquisitions. Incorporating retrospective temporal $$B_0$$ B 0 correction further enhances $${T_2}^*$$ T 2 ∗ reliability and may strengthen the precision of BAT activation studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich (TUM), Munich, Germany. j.raspe@tum.de.
- Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich (TUM), Munich, Germany.
- Deparment of Radiology, LMU University Hospital, Munich, Germany.
- Laboratory of Magnetic Resonance Imaging Systems and Methods, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
- CIBM Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.
Förderung
- Deutsche Forschungsgemeinschaft
- Technische Universität München
Zitieren
APA
Raspe, J., Stelter, J., Braun, P., Junker, D., Wu, M., & Karampinos, D. C. (2025). Motion-robust proton density fat fraction and $${T_2}^*$$ mapping in supraclavicular adipose tissue using radial stack-of-stars imaging. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01302-x
Vancouver
Raspe J, Stelter J, Braun P, Junker D, Wu M, Karampinos DC. Motion-robust proton density fat fraction and $${T_2}^*$$ mapping in supraclavicular adipose tissue using radial stack-of-stars imaging. Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01302-x
BibTeX
@article{Raspe2025,
author = {Raspe, Johannes and Stelter, Jonathan and Braun, Philipp and Junker, Daniela and Wu, Mingming and Karampinos, Dimitrios C},
title = {Motion-robust proton density fat fraction and $$T_2^*$$ mapping in supraclavicular adipose tissue using radial stack-of-stars imaging},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2025},
doi = {10.1007/s10334-025-01302-x}
}
EUVIMED