Learning‐based motion artifact correction in the Z‐spectral domain for chemical exchange saturation transfer MRI
Magnetic Resonance in Medicine · 2025-07 · 94 (1) · 331-345
DOI: 10.1002/mrm.30440 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 20.01.2025. Verfasst von Munendra Singh und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Johns Hopkins University, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Deep Learning. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIBIB NIH HHS, NICHD NIH HHS, NINDS NIH HHS.
Abstract (Originalsprache)
Purpose
To develop and evaluate a physics‐driven, saturation contrast‐aware, deep‐learning‐based framework for motion artifact correction in CEST MRI.
Methods
A neural network was designed to correct motion artifacts directly from a Z‐spectrum frequency (Ω) domain rather than an image spatial domain. Motion artifacts were simulated by modeling 3D rigid‐body motion and readout‐related motion during k‐space sampling. A saturation‐contrast‐specific loss function was added to preserve amide proton transfer (APT) contrast, as well as enforce image alignment between motion‐corrected and ground‐truth images. The proposed neural network was evaluated on simulation data and demonstrated in healthy volunteers and brain tumor patients.
Results
The experimental results showed the effectiveness of motion artifact correction in the Z‐spectrum frequency domain (MOCO Ω ) compared to in the image spatial domain. In addition, a temporal convolution applied to a dynamic saturation image series was able to leverage motion artifacts to improve reconstruction results as a denoising process. The MOCO Ω outperformed existing techniques for motion correction in terms of image quality and computational efficiency. At 3 T, human experiments showed that the root mean squared error (RMSE) of APT images decreased from 4.7% to 2.1% at 1 μT and from 6.2% to 3.5% at 1.5 μT in case of “moderate” motion and from 8.7% to 2.8% at 1 μT and from 12.7% to 4.5% at 1.5 μT in case of “severe” motion, after motion artifact correction.
Conclusion
The MOCO Ω could effectively correct motion artifacts in CEST MRI without compromising saturation transfer contrast.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Johns Hopkins University, Baltimore, Maryland, USA.
- Department of Oncology, Johns Hopkins University, Baltimore, Maryland, USA.
- Department of Neurology, Johns Hopkins University, Baltimore, Maryland, USA.
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
ORCID-Profile: Jinyuan Zhou, Hye-Young Heo
Förderung
- NIBIB NIH HHS
- NICHD NIH HHS
- NINDS NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Singh, M., Mahmud, S. Z., Yedavalli, V., Zhou, J., Kamson, D. O., van Zijl, P., & Heo, H. Y. (2025). Learning‐based motion artifact correction in the Z‐spectral domain for chemical exchange saturation transfer MRI. Magnetic Resonance in Medicine, 94(1), 331-345. https://doi.org/10.1002/mrm.30440
Vancouver
Singh M, Mahmud SZ, Yedavalli V, Zhou J, Kamson DO, van Zijl P, et al. Learning‐based motion artifact correction in the Z‐spectral domain for chemical exchange saturation transfer MRI. Magnetic Resonance in Medicine. 2025;94(1):331-345. doi:10.1002/mrm.30440
BibTeX
@article{Singh2025,
author = {Singh, Munendra and Mahmud, Sultan Z and Yedavalli, Vivek and Zhou, Jinyuan and Kamson, David Olayinka and van Zijl, Peter and Heo, Hye-Young},
title = {Learning‐based motion artifact correction in the Z‐spectral domain for chemical exchange saturation transfer MRI},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {94},
number = {1},
pages = {331--345},
doi = {10.1002/mrm.30440}
}
EUVIMED