Transpulmonary cardiac output with room temperature saline is accurate and tracks directional changes in anesthetized dogs
American Journal of Veterinary Research · 2024
DOI: 10.2460/ajvr.24.05.0154 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2024. Verfasst von Cheyenne J Cannarozzo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cornell University Hospital for Animals, College of Veterinary Medicine, Cornell University, Ithaca, NY. Hauptthemen laut MEDLINE: Thermodilution, Cardiac Output. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVE To assess the performance of transpulmonary thermodilution (TPTD) using room-temperature saline (CO RT ) and waveform-derived continuous CO (CCO) compared with TPTD using iced saline (CO ICED ) as the indicator for measurements of CO in isoflurane-anesthetized dogs. METHODS 8 Beagles aged 1 to 2 years (7.4 to 11.2 kg) were enrolled in this experimental study from March 21 to 31, 2023. Dogs were anesthetized with 0.01 mg/kg acepromazine, 5 to 6 mg/kg propofol, and isoflurane and were mechanically ventilated. Dogs were instrumented with a central venous catheter and a femoral arterial catheter equipped with a thermistor. The CO ICED , CO RT , and pulse wave-derived CCO values were obtained at baseline, during infusions of phenylephrine and norepinephrine, and during blood withdrawal and replacement. Data were analyzed with a mixed effect model, Bland-Altman plots, and concordance. Percent error was calculated. P < .05 was used for significance. RESULTS Data were collected from 8 dogs. Significant effects of time and the interaction of time and method were found. Bland-Altman plots showed negligible bias with limits of agreement between −0.35 and 0.25 L/min for CO RT versus CO ICED and −1.23 and 1.15 L/min for CCO versus CO ICED . Percent errors were 17.7% and 66.6%, respectively. In the 4-quadrant plots, the concordance rate was 95% and 68% for measurements obtained with CO RT and for CCO, respectively. CONCLUSIONS Transpulmonary thermodilution using room temperature saline was accurate and able to track changes in CO. Continuous CO had a large percent error and low tracking ability. CLINICAL RELEVANCE Transpulmonary thermodilution using room temperature saline is reliable for monitoring CO and obviates the need for iced preparations in clinical scenarios.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Cornell University Hospital for Animals, College of Veterinary Medicine, Cornell University, Ithaca, NY.
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY.
ORCID-Profile: Cheyenne J Cannarozzo, Manuel Martin-Flores
Zitieren
APA
Cannarozzo, C. J., Araos, J., & Martin-Flores, M. (2024). Transpulmonary cardiac output with room temperature saline is accurate and tracks directional changes in anesthetized dogs. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.24.05.0154
Vancouver
Cannarozzo CJ, Araos J, Martin-Flores M. Transpulmonary cardiac output with room temperature saline is accurate and tracks directional changes in anesthetized dogs. American Journal of Veterinary Research. 2024. doi:10.2460/ajvr.24.05.0154
BibTeX
@article{Cannarozzo2024,
author = {Cannarozzo, Cheyenne J and Araos, Joaquin and Martin-Flores, Manuel},
title = {Transpulmonary cardiac output with room temperature saline is accurate and tracks directional changes in anesthetized dogs},
journal = {American Journal of Veterinary Research},
year = {2024},
doi = {10.2460/ajvr.24.05.0154}
}
EUVIMED