EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation of cardiac output and Hypotension Prediction Index using HemoSphere Acumen IQ Monitoring System in sevoflurane-anesthetized dogs

Vaidehi V Paranjape, Tayla Regenbaum, Syon Link, Aliya Magee, Chin-Chi Liu, Jeannette Cremer

Veterinary Anaesthesia and Analgesia · 2026

DOI: 10.1016/j.vaa.2025.10.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2026. Verfasst von Vaidehi V Paranjape und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA. Electronic address: vparanjape24…. Hauptthemen laut MEDLINE: Sevoflurane, Anesthetics, Inhalation, Cardiac Output, Hypotension. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Virginia-Maryland College of Veterinary Medicine.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To evaluate agreement between cardiac output (CO) from intermittent pulmonary artery thermodilution (iPATD-CO) and HemoSphere with Acumen IQ sensor (HSIQ-CO) in sevoflurane-anesthetized, normovolemic and hypovolemic dogs. Also, to analyze HSIQ-derived Hypotension Prediction Index (HPI) trends, and investigate its relationship with invasive mean arterial blood pressure (MAP). STUDY DESIGN: Blinded, nonrandomized, experimental observational study. ANIMALS: Eight mixed-breed female intact dogs. METHODS: Dogs were anesthetized on two occasions. In both anesthetic events, iPATD-CO and HSIQ-CO (via dorsal metatarsal artery) were measured 10 times every 10 minutes during normovolemia and 10 times every 10 minutes starting 20 minutes after a 15% blood loss (hypovolemia). Agreement between iPATD-CO and HSIQ-CO was assessed with Bland-Altman, four-quadrant and polar plot analyses. To evaluate MAP-HPI relationship, 100 standardized time points per dog per anesthetic event were uniformly sampled across the anesthetic period from instrumentation to recovery. Area under the receiver operating characteristic (AUROC) curve was used to compare HPI with short-term MAP changes (1-5 minutes) for predicting hypotension (MAP ≤ 65 mmHg > 1 minute) at 5, 10 and 15 minutes. Youden's index provided optimal HPI thresholds for predicting hypotension. RESULTS: HSIQ-CO showed significant overestimation which increased further with hypovolemia. HSIQ-CO measurements had a high percentage error (73%), and poor trending compared with iPATD-CO. HPI strongly predicted hypotension (AUROC > 0.90), outperforming short-term MAP fluctuations (AUROC ≈ 0.50). Optimal HPI thresholds of 97-98 accurately predicted hypotension 15 minutes before onset. CONCLUSIONS AND CLINICAL RELEVANCE: HSIQ proved unreliable for CO measurement; however, HPI accurately predicted hypotension up to 15 minutes, highlighting its potential clinical utility in veterinary anesthesia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SevofluraneAnesthetics, InhalationCardiac OutputHypotensionDog DiseasesAnesthesia, InhalationAnimalsDogsFemaleThermodilution

Stichwörter der Autor:innen

absolute hypovolemiaartificial intelligencehemorrhagehypotensionmean arterial blood pressurepulmonary artery thermodilution

Substanzen

SevofluraneAnesthetics, Inhalation

Autor:innen und Institutionen

  • Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA. Electronic address: vparanjape24@gmail.com.
  • Department of Veterinary Clinical Sciences, Louisiana State University School of Veterinary Medicine, Baton Rouge, LA, USA.
  • Office of Research and Graduate Education, Louisiana State University School of Veterinary Medicine, Baton Rouge, LA, USA.

Förderung

  • Virginia-Maryland College of Veterinary Medicine

Zitieren

APA

Paranjape, V. V., Regenbaum, T., Link, S., Magee, A., Liu, C. C., & Cremer, J. (2026). Evaluation of cardiac output and Hypotension Prediction Index using HemoSphere Acumen IQ Monitoring System in sevoflurane-anesthetized dogs. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2025.10.012

Vancouver

Paranjape VV, Regenbaum T, Link S, Magee A, Liu CC, Cremer J. Evaluation of cardiac output and Hypotension Prediction Index using HemoSphere Acumen IQ Monitoring System in sevoflurane-anesthetized dogs. Veterinary Anaesthesia and Analgesia. 2026. doi:10.1016/j.vaa.2025.10.012

BibTeX
@article{Paranjape2026,
  author = {Paranjape, Vaidehi V and Regenbaum, Tayla and Link, Syon and Magee, Aliya and Liu, Chin-Chi and Cremer, Jeannette},
  title = {Evaluation of cardiac output and Hypotension Prediction Index using HemoSphere Acumen IQ Monitoring System in sevoflurane-anesthetized dogs},
  journal = {Veterinary Anaesthesia and Analgesia},
  year = {2026},
  doi = {10.1016/j.vaa.2025.10.012}
}
Kostenlos starten →