Correlation, agreement and concordance of cardiac output estimated by transthoracic ultrasound and transesophageal Doppler with pulmonary artery thermodilution in anesthetized cats
Veterinary Anaesthesia and Analgesia · 2024
DOI: 10.1016/j.vaa.2024.08.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2024. Verfasst von Bruno H Pypendop und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, USA. Electronic address: bhpype…. Hauptthemen laut MEDLINE: Cardiac Output, Thermodilution, Pulmonary Artery. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, NCATS NIH HHS.
Abstract (Originalsprache)
OBJECTIVE: To characterize the correlation, agreement and concordance of cardiac output (CO) measured with transthoracic ultrasound and the correlation and concordance of aortic blood flow (ABF) minute distance (MD) measured by transesophageal Doppler with CO measured by pulmonary artery thermodilution (PATD) in cats. STUDY DESIGN: Experimental study. ANIMALS: A group of six healthy male neutered cats, aged 2-8 years and weighing 5.3 ± 0.3 kg. METHODS: Cats were anesthetized with isoflurane in oxygen. CO was measured by PATD (COPATD) and transthoracic echocardiography (COECHO). ABF MD was measured using an esophageal Doppler flow probe aligned with descending ABF. All measurements were made under three conditions: dexmedetomidine (20 μg kg-1) intravenously; atipamezole (200 μg kg-1) intramuscularly and atropine (20 μg kg-1) intravenously as needed to achieve a minimum heart rate of 140 beats minute-1; and dopamine (20 μg kg-1 minute-1) intravenously in that order. Correlation between COPATD and COECHO, and COPATD and Doppler MD was evaluated using repeated measures correlation. Agreement between COPATD and COECHO was evaluated using Bland-Altman method. Differences between consecutive pairs of CO measurements were calculated for concordance analysis. RESULTS: Correlation between COPATD and COECHO and between COPATD and MD was significant (p 27% and upper limits of agreement of 66% were found between COPATD and COECHO. Concordance rate with COPATD was 76-80% for COECHO and 72% for MD. CONCLUSIONS AND CLINICAL RELEVANCE: Echocardiographic methods for the measurement of CO showed poor agreement and concordance with PATD. MD showed poor concordance with PATD. As such, these methods cannot be used as an alternative to PATD nor can they appropriately track changes in CO in anesthetized cats.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, USA. Electronic address: bhpypendop@ucdavis.edu.
- Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California, Davis, CA, USA; Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh…
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, USA.
Förderung
- NHLBI NIH HHS
- NCATS NIH HHS
Zitieren
APA
Pypendop, B. H., Rivas, V. N., Bueno, M. C., Chohan, A. S., Barter, L. S., & Stern, J. A. (2024). Correlation, agreement and concordance of cardiac output estimated by transthoracic ultrasound and transesophageal Doppler with pulmonary artery thermodilution in anesthetized cats. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2024.08.006
Vancouver
Pypendop BH, Rivas VN, Bueno MC, Chohan AS, Barter LS, Stern JA. Correlation, agreement and concordance of cardiac output estimated by transthoracic ultrasound and transesophageal Doppler with pulmonary artery thermodilution in anesthetized cats. Veterinary Anaesthesia and Analgesia. 2024. doi:10.1016/j.vaa.2024.08.006
BibTeX
@article{Pypendop2024,
author = {Pypendop, Bruno H and Rivas, Victor N and Bueno, Melissa Couto and Chohan, Amandeep S and Barter, Linda S and Stern, Joshua A},
title = {Correlation, agreement and concordance of cardiac output estimated by transthoracic ultrasound and transesophageal Doppler with pulmonary artery thermodilution in anesthetized cats},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2024},
doi = {10.1016/j.vaa.2024.08.006}
}