Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs
American Journal of Veterinary Research · 2023
DOI: 10.2460/ajvr.23.05.0101 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2023. Verfasst von Vaidehi V Paranjape und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Virginia Polytechnic Institute and State University, …. Hauptthemen laut MEDLINE: Pulmonary Artery, Isoflurane. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVE To compare cardiac output (CO) measurements by transesophageal echocardiography (TEE CO ) and esophageal Doppler monitor (EDM CO ) with pulmonary artery thermodilution (PATD CO ) in anesthetized dogs subjected to pharmacological interventions. The effect of treatments on EDM-derived indexes was also investigated. ANIMALS 6 healthy male dogs (10.8 ± 0.7 kg). METHODS Dogs were anesthetized with propofol and isoflurane, mechanically ventilated, and monitored with invasive mean arterial pressure (MAP), end-tidal isoflurane concentration (ET ISO ), PATD CO , TEE CO , EDM CO , and EDM-derived indexes. Four treatments were administered to all dogs by randomization. Baseline data were collected before each treatment: (1) dobutamine infusion; (2) esmolol infusion; (3) phenylephrine infusion; and (4) ET ISO > 3%. Data were collected after 10-minute stabilization and after 30 minutes of washout between treatments. Statistical tests were pairwise t test, Bland-Altman analysis, Lin's concordance correlation (ρ c ), and polar plot analysis with P < .05 set as significance. RESULTS The mean ± SD relative bias (limits of agreement) for TEE CO was 0.35 ± 25.2% (−49.1% to 49.8%) and for EDM CO was −27.2 ± 22.5% (−71.4% to 17%) versus PATD CO . The percent error for TEE CO and EDM CO was 27.6% and 44.1%, respectively. The ρ c value was 0.82 for TEE CO and 0.66 for EDM CO . TEE CO and EDM CO showed good trending ability. EDM-derived indexes displayed significant changes specific to the drug administered ( P < .001). CLINICAL RELEVANCE For minimally invasive CO monitoring, TEE may provide more favorable performance than EDM in clinical settings; however, EDM-derived indexes yield valuable hemodynamic information that reliably follows trends in CO, thus supporting critical decision-making in canine patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Virginia Polytechnic Institute and State University, Blacksburg, VA.
- Pet Urgent Response and Emergency, Jacksonville, FL.
- Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA.
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH.
Zitieren
APA
Paranjape, V. V., Pereira, F. L. G., Menciotti, G., Saksena, S., Guerrero, N. H., & Pereira, C. H. R. (2023). Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.23.05.0101
Vancouver
Paranjape VV, Pereira FLG, Menciotti G, Saksena S, Guerrero NH, Pereira CHR. Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs. American Journal of Veterinary Research. 2023. doi:10.2460/ajvr.23.05.0101
BibTeX
@article{Paranjape2023,
author = {Paranjape, Vaidehi V and Pereira, Fernando L Garcia and Menciotti, Giulio and Saksena, Siddharth and Guerrero, Natalia Henao and Pereira, Carolina H Ricco},
title = {Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs},
journal = {American Journal of Veterinary Research},
year = {2023},
doi = {10.2460/ajvr.23.05.0101}
}
EUVIMED