EUVIMEDSkopri EUVIMED
ValidierungsstudieOpen access

Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study

Payal Shah iD, Sabrina Sy iD, Mingjing Chen iD, Michael Ck Khoo iD, Thomas D Coates iD, Saranya Veluswamy iD

JMIR Human Factors · 2026

DOI: 10.2196/75465 ↗

At a glance

Validierungsstudie in JMIR Human Factors, 2026. Written by Payal Shah and 5 co-authors. Institution: Division of Hematology, Cancer and Blood Disease Institute, Children's Hospital Los Angeles, University of Southern California, 4650 Sunset Boulevard…. Major MEDLINE topics: Photoplethysmography, Wearable Electronic Devices, Anemia, Sickle Cell, Vasoconstriction. 19 references. The full text is freely available in PubMed Central. Funded by: NHLBI NIH HHS.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Entrapment of sickled red blood cells in the microvasculature leads to sudden painful vaso-occlusive crises (VOCs) in sickle cell disease (SCD). This is potentially triggered by autonomic nervous system–mediated vasoconstriction in the microvasculature. Indeed, vasoconstriction biomarkers derived from a single night of laboratory-based fingertip photoplethysmography (PPG) recording were predictive of a higher frequency of future VOC in SCD. Noninvasive, remote, and longitudinal monitoring of autonomic vasoreactivity will facilitate the development of predictive biomarkers of imminent VOC.

Objective

This study aimed to assess the feasibility and performance of a wearable wristband device to longitudinally monitor nocturnal peripheral autonomic vasoreactivity and to cross-validate the vasoconstriction parameters across the “gold-standard” finger sensor.

Methods

A total of 12 patients with SCD and 6 healthy controls were recruited to wear a wristband device (Biostrap) with a PPG sensor on a nightly basis. For cross-validation studies, 50% (3/6) controls wore both the wristband and a sleep monitoring device (AliceNightOne) with a finger PPG sensor. We quantified autonomic vasoreactivity by processing PPG signals and deriving vasoconstriction parameters—magnitude of vasoconstriction (Mvasoc) and photoplethysmography amplitude coefficient of variation (PPGampCV). We performed a correlation analysis of the vasoconstriction parameters within each device to investigate whether Mvasoc and PPGampCV can be used as surrogate markers of vasoconstriction, and then cross-validated the PPGampCV across the wristband and finger PPG devices.

Results

A total of 131 nocturnal PPG recordings were made with a wristband device (1‐19 nights per participant; patients with SCD: n=79, 60%; controls: n=52, 40%). A total of 9 nocturnal recordings (3 nights per participant) were made with both wristband and finger sensor devices. Longitudinal continuous PPG recordings were feasible with the wearable device, with significant within-night and night-to-night variability in vasoconstriction parameters, suggesting dynamic changes in autonomic vasoreactivity. Mvasoc and PPGampCV significantly correlated within devices—the maximum overnight correlation was 0.82 ( P

Subjects

MeSH terms (MEDLINE)

PhotoplethysmographyWearable Electronic DevicesAnemia, Sickle CellVasoconstrictionHumansMaleFemaleAdultFeasibility StudiesBiomarkers

Author keywords

microvascular blood flowremote monitoringsickle cell diseasevasoconstrictionwearable devices

Substances

Biomarkers

Authors and institutions

  • Division of Hematology, Cancer and Blood Disease Institute, Children's Hospital Los Angeles, University of Southern California, 4650 Sunset Boulevard, Los Angeles, CA, 90027, United States, 1 3233615507.
  • Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States.

ORCID profiles: Payal Shah, Sabrina Sy, Mingjing Chen, Michael Ck Khoo, Thomas D Coates, Saranya Veluswamy

Funding

  • NHLBI NIH HHS

Cite

APA

Shah, P., Sy, S., Chen, M., Khoo, M. C., Coates, T. D., & Veluswamy, S. (2026). Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study. JMIR Human Factors. https://doi.org/10.2196/75465

Vancouver

Shah P, Sy S, Chen M, Khoo MC, Coates TD, Veluswamy S. Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study. JMIR Human Factors. 2026. doi:10.2196/75465

BibTeX
@article{Shah2026,
  author = {Shah, Payal and Sy, Sabrina and Chen, Mingjing and Khoo, Michael Ck and Coates, Thomas D and Veluswamy, Saranya},
  title = {Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study},
  journal = {JMIR Human Factors},
  year = {2026},
  doi = {10.2196/75465}
}
Start for free →