EUVIMEDEUVIMED entdecken
Beobachtungsstudie

A Wearable Multimodal Vital Sign Detection and Photobiomodulation Device for Early Brain Injury Treatment: A Feasibility Study

Debbie Kantor iD, Michael Blaivas, Elliot Kantor, Jennifer Greer, Kunal Mitra, Mercy Golda Sam Raj, Caroline Moore, Yajie Dong, William David Freeman

Military Medicine · 2025

DOI: 10.1093/milmed/usaf201 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Military Medicine, 2025. Verfasst von Debbie Kantor und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Research & Development, Hero Medical Technologies, Ponte Vedra Beach, FL 32082, United States. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Vital Signs, Brain Injuries, Low-Level Light Therapy. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Hero Medical Technologies.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traumatic brain injury (TBI), particularly among military personnel, poses significant challenges in acute management and long-term outcomes. Difficult-to-diagnose autoregulatory and inflammatory changes lead to neurocognitive impairment, anxiety, sleep disturbance, and chronic pain. To optimize readiness and test therapeutics for both diagnostic and future TBI treatments, this feasibility study introduces a novel wearable multimodal platform that integrates photoplethysmography and infra-red (IR) sensing from a camera and a wearable sensor to detect vital signs and then leverages machine learning (ML) to predict the need for acute treatment. This prospective observational study involving 28 healthy volunteers simulated a triage emergency room workflow to test sensor accuracy and mobile app functionality. The wearable device demonstrated high accuracy in pulse rate (mean error 7.3%) and oxygen saturation (mean error −1.2%) compared to standard-of-care devices. Camera-based pulse and respiratory rate, and wearable pulse, oxygen, and temperature sensing were tested in a mock triage setting to simulate activation of light-based treatment upon detection of physiological changes of concern after acute TBI. Preliminary ML models to predict hypotension and pain based on retrospective data achieved 98.4% and 93% accuracy but showed limitations in prospective real-time applications. This study provided insights to prepare for future iterations that will integrate near-IR spectroscopy to detect cerebral oximetry, and quantum dot light-emitting diodes to activate light-based treatment (photobiomodulation) from within a wearable head dressing. The findings underscore the potential of this platform to bridge critical gaps in acute TBI care through early detection and future therapeutic intervention. Further development is needed to address environmental challenges, improve accuracy across diverse populations, and refine the device for real-time clinical use. This innovative approach has the potential to revolutionize TBI care by bridging current gaps in diagnostic and therapeutic management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesVital SignsBrain InjuriesLow-Level Light TherapyHumansFeasibility StudiesProspective StudiesAdultMaleFemalePhotoplethysmography

Autor:innen und Institutionen

  • Department of Research & Development, Hero Medical Technologies, Ponte Vedra Beach, FL 32082, United States.
  • Department of Biomedical Engineering, Florida Institute of Technology, Melbourne, FL 32901, United States.
  • Department of Materials Science and Engineering, University of Central Florida, Orlando, FL 3281, United States.
  • Department of Neurology, Mayo Clinic, Jacksonville, FL 32224, United States.

ORCID-Profile: Debbie Kantor

Förderung

  • Hero Medical Technologies

Zitieren

APA

Kantor, D., Blaivas, M., Kantor, E., Greer, J., Mitra, K., Raj, M. G. S., Moore, C., Dong, Y., & Freeman, W. D. (2025). A Wearable Multimodal Vital Sign Detection and Photobiomodulation Device for Early Brain Injury Treatment: A Feasibility Study. Military Medicine. https://doi.org/10.1093/milmed/usaf201

Vancouver

Kantor D, Blaivas M, Kantor E, Greer J, Mitra K, Raj MGS, et al. A Wearable Multimodal Vital Sign Detection and Photobiomodulation Device for Early Brain Injury Treatment: A Feasibility Study. Military Medicine. 2025. doi:10.1093/milmed/usaf201

BibTeX
@article{Kantor2025,
  author = {Kantor, Debbie and Blaivas, Michael and Kantor, Elliot and Greer, Jennifer and Mitra, Kunal and Raj, Mercy Golda Sam and Moore, Caroline and Dong, Yajie and Freeman, William David},
  title = {A Wearable Multimodal Vital Sign Detection and Photobiomodulation Device for Early Brain Injury Treatment: A Feasibility Study},
  journal = {Military Medicine},
  year = {2025},
  doi = {10.1093/milmed/usaf201}
}
Kostenlos starten →