Feasibility of Electrodermal Activity and Photoplethysmography Data Acquisition at the Foot Using a Sock Form Factor
Sensors · 2023
DOI: 10.3390/s23020620 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Afonso Fortes Ferreira und 4 weiteren Autor:innen. Beteiligte Einrichtung: Instituto Superior Técnico (IST), Av. Rovisco Pais n. 1, 1049-001 Lisboa, Portugal. Hauptthemen laut MEDLINE: Galvanic Skin Response, Wearable Electronic Devices. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, European Regional Development Fund, Ministério da Ciência, Tecnologia e Ensino Superior (MCTES).
Abstract (Originalsprache)
Wearable devices have been shown to play an important role in disease prevention and health management, through the multimodal acquisition of peripheral biosignals. However, many of these wearables are exposed, limiting their long-term acceptability by some user groups. To overcome this, a wearable smart sock integrating a PPG sensor and an EDA sensor with textile electrodes was developed. Using the smart sock, EDA and PPG measurements at the foot/ankle were performed in test populations of 19 and 15 subjects, respectively. Both measurements were validated by simultaneously recording the same signals with a standard device at the hand. For the EDA measurements, Pearson correlations of up to 0.95 were obtained for the SCL component, and a mean consensus of 69% for peaks detected in the two locations was obtained. As for the PPG measurements, after fine-tuning the automatic detection of systolic peaks, the index finger and ankle, accuracies of 99.46% and 87.85% were obtained, respectively. Moreover, an HR estimation error of 17.40±14.80 Beats-Per-Minute (BPM) was obtained. Overall, the results support the feasibility of this wearable form factor for unobtrusive EDA and PPG monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Instituto Superior Técnico (IST), Av. Rovisco Pais n. 1, 1049-001 Lisboa, Portugal.
- Instituto de Telecomunicações (IT), Av. Rovisco Pais n. 1, Torre Norte-Piso 10, 1049-001 Lisboa, Portugal.
- Instituto de Engenharia de Sistemas e Computadores-Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol 9, 1000-019 Lisboa, Portugal.
- Meia Mania Lda, Zona Industrial dos Matinhos Pav. 4/5, 3200-100 Lousã, Portugal.
ORCID-Profile: Afonso Fortes Ferreira, Hugo Plácido da Silva, Helena Alves, Ana Fred
Förderung
- Fundação para a Ciência e Tecnologia
- European Regional Development Fund
- Ministério da Ciência, Tecnologia e Ensino Superior (MCTES)
- EU funds
- Instituto de Telecomunicações (IT)
- European Regional Development Fund (FEDER) through the Operational Competitiveness and Internationalization Programme (COMPETE 2020)
- National Funds (OE)
Zitieren
APA
Ferreira, A. F., da Silva, H. P., Alves, H., Marques, N., & Fred, A. (2023). Feasibility of Electrodermal Activity and Photoplethysmography Data Acquisition at the Foot Using a Sock Form Factor. Sensors. https://doi.org/10.3390/s23020620
Vancouver
Ferreira AF, da Silva HP, Alves H, Marques N, Fred A. Feasibility of Electrodermal Activity and Photoplethysmography Data Acquisition at the Foot Using a Sock Form Factor. Sensors. 2023. doi:10.3390/s23020620
BibTeX
@article{Ferreira2023,
author = {Ferreira, Afonso Fortes and da Silva, Hugo Plácido and Alves, Helena and Marques, Nuno and Fred, Ana},
title = {Feasibility of Electrodermal Activity and Photoplethysmography Data Acquisition at the Foot Using a Sock Form Factor},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23020620}
}
EUVIMED