Investigation and Validation of New Heart Rate Measurement Sites for Wearable Technologies
Sensors · 2025
DOI: 10.3390/s25072069 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Jumana Matouq und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Applied Medical Sciences, German Jordanian University, Amman 11180, Jordan. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Heart Rate. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A recent focus has been on developing wearable health solutions that allow users to seamlessly track their health metrics during their daily activities, providing convenient and continuous access to vital physiological data. This work investigates a heart rate (HR) monitoring system and compares the HR measurement from two potential sites for foot wearable technologies. The proposed system used a commercially available photoplethysmography sensor (PPG), microcontroller, Bluetooth module, and mobile phone application. HR measurements were obtained from two anatomical sites, i.e., the dorsalis pedis artery (DPA) and the posterior tibial artery (PTA), and compared to readings from the Apple Smartwatch during standing and walking tasks. The system was validated on twenty healthy volunteers, employing ANOVA and Bland-Altman analysis to assess the accuracy and consistency of the HR measurements. During the standing test, the Bland-Altman analysis showed a mean difference of 0.08 bpm for the DPA compared to a smaller mean difference of 0.069 bpm for the PTA. On the other hand, the walking test showed a mean difference of 0.255 bpm and −0.06 bpm for the DPA and PTA, respectively. These results showed a high level of agreement between the HR measurements collected at the foot with the smartwatch measurements, with superiority for the HR measurements collected at the PTA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, School of Applied Medical Sciences, German Jordanian University, Amman 11180, Jordan.
- Institute of Medical Device Technology, University of Stuttgart, 70569 Stuttgart, Germany.
ORCID-Profile: Peter P Pott
Zitieren
APA
Matouq, J., AlSaaideh, I., Hatahet, O., & Pott, P. P. (2025). Investigation and Validation of New Heart Rate Measurement Sites for Wearable Technologies. Sensors. https://doi.org/10.3390/s25072069
Vancouver
Matouq J, AlSaaideh I, Hatahet O, Pott PP. Investigation and Validation of New Heart Rate Measurement Sites for Wearable Technologies. Sensors. 2025. doi:10.3390/s25072069
BibTeX
@article{Matouq2025,
author = {Matouq, Jumana and AlSaaideh, Ibrahim and Hatahet, Oula and Pott, Peter P},
title = {Investigation and Validation of New Heart Rate Measurement Sites for Wearable Technologies},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25072069}
}
EUVIMED