Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study
JMIR Human Factors · 2026
DOI: 10.2196/75465 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift JMIR Human Factors, 2026. Verfasst von Payal Shah und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Hematology, Cancer and Blood Disease Institute, Children's Hospital Los Angeles, University of Southern California, 4650 Sunset Boulevard…. Hauptthemen laut MEDLINE: Photoplethysmography, Wearable Electronic Devices, Anemia, Sickle Cell, Vasoconstriction. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.
Abstract (Originalsprache)
Background
Entrapment of sickled red blood cells in the microvasculature leads to sudden painful vaso-occlusive crises (VOCs) in sickle cell disease (SCD). This is potentially triggered by autonomic nervous system–mediated vasoconstriction in the microvasculature. Indeed, vasoconstriction biomarkers derived from a single night of laboratory-based fingertip photoplethysmography (PPG) recording were predictive of a higher frequency of future VOC in SCD. Noninvasive, remote, and longitudinal monitoring of autonomic vasoreactivity will facilitate the development of predictive biomarkers of imminent VOC.
Objective
This study aimed to assess the feasibility and performance of a wearable wristband device to longitudinally monitor nocturnal peripheral autonomic vasoreactivity and to cross-validate the vasoconstriction parameters across the “gold-standard” finger sensor.
Methods
A total of 12 patients with SCD and 6 healthy controls were recruited to wear a wristband device (Biostrap) with a PPG sensor on a nightly basis. For cross-validation studies, 50% (3/6) controls wore both the wristband and a sleep monitoring device (AliceNightOne) with a finger PPG sensor. We quantified autonomic vasoreactivity by processing PPG signals and deriving vasoconstriction parameters—magnitude of vasoconstriction (Mvasoc) and photoplethysmography amplitude coefficient of variation (PPGampCV). We performed a correlation analysis of the vasoconstriction parameters within each device to investigate whether Mvasoc and PPGampCV can be used as surrogate markers of vasoconstriction, and then cross-validated the PPGampCV across the wristband and finger PPG devices.
Results
A total of 131 nocturnal PPG recordings were made with a wristband device (1‐19 nights per participant; patients with SCD: n=79, 60%; controls: n=52, 40%). A total of 9 nocturnal recordings (3 nights per participant) were made with both wristband and finger sensor devices. Longitudinal continuous PPG recordings were feasible with the wearable device, with significant within-night and night-to-night variability in vasoconstriction parameters, suggesting dynamic changes in autonomic vasoreactivity. Mvasoc and PPGampCV significantly correlated within devices—the maximum overnight correlation was 0.82 ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Hematology, Cancer and Blood Disease Institute, Children's Hospital Los Angeles, University of Southern California, 4650 Sunset Boulevard, Los Angeles, CA, 90027, United States, 1 3233615507.
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States.
ORCID-Profile: Payal Shah, Sabrina Sy, Mingjing Chen, Michael Ck Khoo, Thomas D Coates, Saranya Veluswamy
Förderung
- NHLBI NIH HHS
Zitieren
APA
Shah, P., Sy, S., Chen, M., Khoo, M. C., Coates, T. D., & Veluswamy, S. (2026). Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study. JMIR Human Factors. https://doi.org/10.2196/75465
Vancouver
Shah P, Sy S, Chen M, Khoo MC, Coates TD, Veluswamy S. Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study. JMIR Human Factors. 2026. doi:10.2196/75465
BibTeX
@article{Shah2026,
author = {Shah, Payal and Sy, Sabrina and Chen, Mingjing and Khoo, Michael Ck and Coates, Thomas D and Veluswamy, Saranya},
title = {Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study},
journal = {JMIR Human Factors},
year = {2026},
doi = {10.2196/75465}
}
EUVIMED