Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study
JMIR Formative Research · 2025
DOI: 10.2196/53645 ↗At a glance
Beobachtungsstudie in JMIR Formative Research, 2025. Written by Hope Davis-Wilson and 10 co-authors. Institution: RTI International, Morrisville, NC, United States. Major MEDLINE topics: Heart Rate, Photoplethysmography, Wearable Electronic Devices. Cited 6 times so far (Crossref); 39 references. The full text is freely available in PubMed Central.
Abstract (original language)
Background
Measuring heart rate variability (HRV) through wearable photoplethysmography sensors from smartwatches is gaining popularity for monitoring many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metrics or algorithm calculations. Research is needed on how to best account for missing data and to assess the accuracy of metrics derived from photoplethysmography sensors.
Objective
This study aimed to evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during activity in real-world settings and to evaluate HRV agreement and consistency between wearable photoplethysmography and gold-standard wearable electrocardiogram (ECG) sensors in real-world settings.
Methods
Healthy participants were outfitted with a smartwatch with a photoplethysmography sensor that collected high-resolution interbeat interval (IBI) data to wear continuously (day and night) for up to 6 months. New datasets were created with various amounts of missing data and then compared with the original (reference) datasets. 5-minute windows of each HRV metric (median IBI, SD of IBI values [STDRR], root-mean-square of the difference in successive IBI values [RMSDRR], low-frequency [LF] power, high-frequency [HF] power, and the ratio of LF to HF power [LF/HF]) were compared between the reference and the missing datasets (10%, 20%, 35%, and 60% missing data). HRV metrics calculated from the photoplethysmography sensor were compared with HRV metrics calculated from a chest-worn ECG sensor.
Results
At rest, median IBI remained stable until at least 60% of data degradation (P=.24), STDRR remained stable until at least 35% of data degradation (P=.02), and RMSDRR remained stable until at least 35% data degradation (P=.001). During the activity, STDRR remained stable until 20% data degradation (P=.02) while median IBI (P=.01) and RMSDRR P
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- RTI International, Morrisville, NC, United States.
ORCID profiles: Hope Davis-Wilson, Meghan Hegarty-Craver, Pooja Gaur, Matthew Boyce, Jonathan R Holt, Edward Preble, Randall Eckhoff, Lei Li, Howard Walls, David Dausch, Dorota Temple
Cite
APA
Davis-Wilson, H., Hegarty-Craver, M., Gaur, P., Boyce, M., Holt, J. R., Preble, E., Eckhoff, R., Li, L., Walls, H., Dausch, D., & Temple, D. (2025). Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study. JMIR Formative Research. https://doi.org/10.2196/53645
Vancouver
Davis-Wilson H, Hegarty-Craver M, Gaur P, Boyce M, Holt JR, Preble E, et al. Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study. JMIR Formative Research. 2025. doi:10.2196/53645
BibTeX
@article{DavisWilson2025,
author = {Davis-Wilson, Hope and Hegarty-Craver, Meghan and Gaur, Pooja and Boyce, Matthew and Holt, Jonathan R and Preble, Edward and Eckhoff, Randall and Li, Lei and Walls, Howard and Dausch, David and Temple, Dorota},
title = {Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study},
journal = {JMIR Formative Research},
year = {2025},
doi = {10.2196/53645}
}
EUVIMED