PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects
Sensors · 2026
DOI: 10.3390/s26102922 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Jason Kostrna und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Teaching and Learning, Florida International University, 11200 SW 8th Street, Miami, FL 33199, USA. Hauptthemen laut MEDLINE: Heart Rate, Skin Pigmentation, Body Composition, Photoplethysmography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. National Science Foundation, National Science Foundation.
Abstract (Originalsprache)
Wearable devices are widely used for heart rate (HR) monitoring, yet their accuracy across varying BMI and Fitzpatrick skin tones remains uncertain. This study evaluated four wrist-worn devices (Apple, Fitbit, Samsung, Garmin) in 58 Hispanic adults with Fitzpatrick skin types III–V during a cycling protocol alternating moderate (64–76% HRmax) and vigorous (77–95% HRmax) intensities. Criterion HR was obtained via Polar H10 ECG, with agreement assessed using mean absolute error (MAE), mean absolute percentage error (MAPE), mean bias, and intraclass correlation coefficients (ICC), complemented by Bland–Altman visualization. All devices showed small but systematic deviations from the ECG criterion (p < 0.001). Apple and Garmin exhibited the lowest MAE, whereas Fitbit and Samsung showed greater error. Within this cohort, greater dispersion of error around the mean bias line in the Bland–Altman plots was observed among participants with higher BMI and darker (Fitzpatrick V) skin tones, consistent with phenotype-linked agreement drift. These findings support inferences about commercial wrist-PPG devices in Hispanic adults with Fitzpatrick III–V and underscore the need for equity-focused algorithm refinement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Teaching and Learning, Florida International University, 11200 SW 8th Street, Miami, FL 33199, USA.
- Department of Dietetics & Nutrition, Florida International University, Miami, FL 33199, USA.
- Department of Biomedical Engineering, Florida International University, Miami, FL 33199, USA.
ORCID-Profile: Jason Kostrna, Ekaterina Oparina, Cristina Palacios, Andres J Rodriguez, JunZhu Pei, Ajmal Ajmal, Jessica C Ramella-Roman
Förderung
- U.S. National Science Foundation
- National Science Foundation
Zitieren
APA
Kostrna, J., Oparina, E., Palacios, C., Rodriguez, A. J., Pei, J., Ajmal, A., & Ramella-Roman, J. C. (2026). PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects. Sensors. https://doi.org/10.3390/s26102922
Vancouver
Kostrna J, Oparina E, Palacios C, Rodriguez AJ, Pei J, Ajmal A, et al. PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects. Sensors. 2026. doi:10.3390/s26102922
BibTeX
@article{Kostrna2026,
author = {Kostrna, Jason and Oparina, Ekaterina and Palacios, Cristina and Rodriguez, Andres J and Pei, JunZhu and Ajmal, Ajmal and Ramella-Roman, Jessica C},
title = {PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26102922}
}
EUVIMED