Kurz gefasst

Vergleichsstudie in der Zeitschrift Sensors, 2025. Verfasst von Nagima Abdrasulova und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Software, Hallym University, 1 Hallymdaehak-gil, Chuncheon 24252, Gangwon-do, Republic of Korea. Hauptthemen laut MEDLINE: Heart Rate, Wearable Electronic Devices, Photoplethysmography. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Regional Innovation System & Education (RISE) program, Ministry of Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photoplethysmography (PPG)-based heart rate variability (HRV) offers a cost-effective alternative to electrocardiography (ECG) for autonomic monitoring in wearable devices. We optimized signal processing on a 16-bit microcontroller by comparing 4th-order equivalent Butterworth and Elliptic IIR bandpass filters (0.8–20 Hz, zero-phase) at 1000, 500, and 250 Hz. Paired PPG–ECG recordings from 10 healthy adults were analyzed for ln HF, ln LF, and ln VLF using Lin’s concordance correlation coefficient (CCC), ±5% equivalence testing (TOST), and Passing–Bablok regression (PBR). Butterworth at 500 Hz preserved near-identity with ECG standard (CCC ≥0.94; TOST met equivalence; PBR slopes/intercepts: ln HF = 0.97x + 0.10, ln LF = 1.02x − 0.07, ln VLF = 1.01x − 0.03), while halving computational load. In contrast, Elliptic at 250 Hz degraded concordance (CCC ≈ 0.64) and failed equivalence, with greater bias from nonlinear phase and ripple-induced distortion. Elliptic performance improved at higher sampling but offered no benefit over Butterworth. These results support zero-phase Butterworth filtering at ≥500 Hz as the optimal balance of fidelity, robustness, and efficiency, enabling reliable PPG-HRV monitoring on low-power devices. As a pilot investigation (n = 10), this study establishes preliminary design parameters and optimal configurations to guide subsequent large-scale clinical validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateWearable Electronic DevicesPhotoplethysmographyHumansAdultSignal Processing, Computer-AssistedMaleElectrocardiographyFemale

Stichwörter der Autor:innen

Butterworth filterIIR filterselliptic filterheart rate variabilityphotoplethysmographysignal processing

Autor:innen und Institutionen

  • Division of Software, Hallym University, 1 Hallymdaehak-gil, Chuncheon 24252, Gangwon-do, Republic of Korea.

Förderung

  • Regional Innovation System & Education (RISE) program
  • Ministry of Education

Zitieren

APA

Abdrasulova, N., Aleksanyan, M., Kim, M. J., & Ahn, J. M. (2025). Butterworth Filtering at 500 Hz Optimizes PPG-Based Heart Rate Variability Analysis for Wearable Devices: A Comparative Study. Sensors. https://doi.org/10.3390/s25227091

Vancouver

Abdrasulova N, Aleksanyan M, Kim MJ, Ahn JM. Butterworth Filtering at 500 Hz Optimizes PPG-Based Heart Rate Variability Analysis for Wearable Devices: A Comparative Study. Sensors. 2025. doi:10.3390/s25227091

BibTeX
@article{Abdrasulova2025,
  author = {Abdrasulova, Nagima and Aleksanyan, Milana and Kim, Min Ju and Ahn, Jae Mok},
  title = {Butterworth Filtering at 500 Hz Optimizes PPG-Based Heart Rate Variability Analysis for Wearable Devices: A Comparative Study},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25227091}
}
Kostenlos starten →