EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research

Mohammadamin Sinichi iD, Martin J Gevonden iD, Lydia Krabbendam iD

Psychophysiology · 2025-02 · 62 (2)

DOI: 10.1111/psyp.70004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Psychophysiology, online erschienen am 04.02.2025. Verfasst von Mohammadamin Sinichi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical, Neuro- & Developmental Psychology, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The…. Hauptthemen laut MEDLINE: Heart Rate, Wearable Electronic Devices, Photoplethysmography, Psychophysiology. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heart rate (HR) and heart rate variability (HRV) are two key measures with significant relevance in psychophysiological studies, and their measurement has become more convenient due to advances in wearable technology. However, photoplethysmography (PPG)‐based wearables pose critical validity concerns. In this study, we validated four PPG wearables: three consumer‐grade devices (Kyto2935, Schone Rhythm 24, and HeartMath Inner Balance Bluetooth) and one research‐grade device (Empatica EmbracePlus, successor to the widely‐used but discontinued Empatica E4). All devices were worn simultaneously by 40 healthy participants who underwent conditions commonly used in laboratory research (seated rest, arithmetic task, recovery, slow‐paced breathing, a neuropsychological task, posture manipulation by standing up) and encountered in ambulatory‐like settings (slow walking and stationary biking), compared against a criterion electrocardiography device, the Vrije Universiteit Ambulatory Monitoring System (VU‐AMS). We determined the signal quality, the linear strength through regression analysis, the bias through Bland–Altman analysis, and the measurement error through mean arctangent absolute percentage error for each condition against the criterion device. We found that the research‐grade device did not outperform the consumer‐grade devices in laboratory conditions. It also showed low agreement with the ECG in ambulatory‐like conditions. In general, devices captured HR more accurately than HRV. Finally, conditions that deviated from baseline settings and involved slight to high movement, negatively impacted the agreement between PPG devices and the criterion. We conclude that PPG devices, even those advertised and designed for research purposes, may pose validity concerns for HRV measurement in conditions other than those similar to resting states.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateWearable Electronic DevicesPhotoplethysmographyPsychophysiologyHumansAdultMaleFemaleYoung AdultElectrocardiographyReproducibility of Results

Autor:innen und Institutionen

  • Department of Clinical, Neuro- & Developmental Psychology, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
  • Institute Brain and Behaviour (iBBA), Amsterdam, The Netherlands.
  • Department of Biological Psychology, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.

ORCID-Profile: Mohammadamin Sinichi, Martin J Gevonden, Lydia Krabbendam

Förderung

  • Wellcome Trust

Zitieren

APA

Sinichi, M., Gevonden, M. J., & Krabbendam, L. (2025). Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research. Psychophysiology, 62(2). https://doi.org/10.1111/psyp.70004

Vancouver

Sinichi M, Gevonden MJ, Krabbendam L. Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research. Psychophysiology. 2025;62(2). doi:10.1111/psyp.70004

BibTeX
@article{Sinichi2025,
  author = {Sinichi, Mohammadamin and Gevonden, Martin J and Krabbendam, Lydia},
  title = {Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research},
  journal = {Psychophysiology},
  year = {2025},
  volume = {62},
  number = {2},
  doi = {10.1111/psyp.70004}
}
Kostenlos starten →