Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study
JMIR Formative Research · 2025
DOI: 10.2196/53645 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift JMIR Formative Research, 2025. Verfasst von Hope Davis-Wilson und 10 weiteren Autor:innen. Beteiligte Einrichtung: RTI International, Morrisville, NC, United States. Hauptthemen laut MEDLINE: Heart Rate, Photoplethysmography, Wearable Electronic Devices. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Measuring heart rate variability (HRV) through wearable photoplethysmography sensors from smartwatches is gaining popularity for monitoring many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metrics or algorithm calculations. Research is needed on how to best account for missing data and to assess the accuracy of metrics derived from photoplethysmography sensors.
Objective
This study aimed to evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during activity in real-world settings and to evaluate HRV agreement and consistency between wearable photoplethysmography and gold-standard wearable electrocardiogram (ECG) sensors in real-world settings.
Methods
Healthy participants were outfitted with a smartwatch with a photoplethysmography sensor that collected high-resolution interbeat interval (IBI) data to wear continuously (day and night) for up to 6 months. New datasets were created with various amounts of missing data and then compared with the original (reference) datasets. 5-minute windows of each HRV metric (median IBI, SD of IBI values [STDRR], root-mean-square of the difference in successive IBI values [RMSDRR], low-frequency [LF] power, high-frequency [HF] power, and the ratio of LF to HF power [LF/HF]) were compared between the reference and the missing datasets (10%, 20%, 35%, and 60% missing data). HRV metrics calculated from the photoplethysmography sensor were compared with HRV metrics calculated from a chest-worn ECG sensor.
Results
At rest, median IBI remained stable until at least 60% of data degradation (P=.24), STDRR remained stable until at least 35% of data degradation (P=.02), and RMSDRR remained stable until at least 35% data degradation (P=.001). During the activity, STDRR remained stable until 20% data degradation (P=.02) while median IBI (P=.01) and RMSDRR P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- RTI International, Morrisville, NC, United States.
ORCID-Profile: Hope Davis-Wilson, Meghan Hegarty-Craver, Pooja Gaur, Matthew Boyce, Jonathan R Holt, Edward Preble, Randall Eckhoff, Lei Li, Howard Walls, David Dausch, Dorota Temple
Zitieren
APA
Davis-Wilson, H., Hegarty-Craver, M., Gaur, P., Boyce, M., Holt, J. R., Preble, E., Eckhoff, R., Li, L., Walls, H., Dausch, D., & Temple, D. (2025). Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study. JMIR Formative Research. https://doi.org/10.2196/53645
Vancouver
Davis-Wilson H, Hegarty-Craver M, Gaur P, Boyce M, Holt JR, Preble E, et al. Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study. JMIR Formative Research. 2025. doi:10.2196/53645
BibTeX
@article{DavisWilson2025,
author = {Davis-Wilson, Hope and Hegarty-Craver, Meghan and Gaur, Pooja and Boyce, Matthew and Holt, Jonathan R and Preble, Edward and Eckhoff, Randall and Li, Lei and Walls, Howard and Dausch, David and Temple, Dorota},
title = {Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study},
journal = {JMIR Formative Research},
year = {2025},
doi = {10.2196/53645}
}
EUVIMED