EUVIMEDEUVIMED entdecken
Evaluationsstudie

Evaluation of CAD-CAM methods for fabrication of removable partial denture frameworks from commercially pure titanium

Kosei Ito, Akinori Tasaka, Hiro Kobayashi, Seiichi Nakata, Shuichiro Yamashita

Journal of Prosthodontic Research · 2026 · 70 (4) · 652-662

DOI: 10.2186/jpr.jpr_d_25_00209 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Prosthodontic Research, 2026. Verfasst von Kosei Ito und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Removable Partial Prosthodontics, Tokyo Dental College, Tokyo, Japan. Hauptthemen laut MEDLINE: Titanium, Computer-Aided Design, Denture, Partial, Removable, Denture Design. Die Arbeit nennt 53 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Commercially pure titanium (CP-Ti) is ideal for removable partial denture (RPD) frameworks owing to its biocompatibility and corrosion resistance; however, conventional casting can introduce defects and dimensional errors. This study compared the shape accuracy, surface roughness, microstructure, and internal pores of CP-Ti RPD frameworks prepared using four CAD-CAM fabrication methods: (1) Ti-resin: casting from a three-dimensional (3D)-printed resin pattern; (2) Ti-wax: casting from a milled wax pattern; (3) Ti-milling: direct milling from a CP-Ti disc; and (4) Ti-SLM: selective laser melting. METHODS: Forty frameworks were prepared for each group (N = 10). Shape accuracy was assessed using 3D data-inspection software, surface roughness was analyzed using laser microscopy, the microstructure was determined using X-ray diffraction, and internal pores were examined using micro-computed tomography. Nonparametric statistics (Kruskal-Wallis and Steel-Dwass tests) were used (P < 0.05). RESULTS: Ti-SLM achieved the highest trueness (median: 0.00 mm; IQR: 0.09 mm) and precision (median: 0.01 mm; IQR: 0.02 mm), while Ti-milling yielded the lowest surface roughness (median arithmetic mean height: 0.61 µm; IQR: 0.05 µm). Internal pores were absent in Ti-milling and minimal in Ti-SLM (0-1), whereas Ti-resin and Ti-wax produced 319 and 171 pores (median), respectively. Significant inter-method differences were found in shape accuracy, surface roughness, and pore counts (P < 0.05). CONCLUSIONS: The fabrication method affected the dimensional accuracy, surface conditions, crystalline features, and internal pores of the CP-Ti frameworks. Ti-milling and Ti-SLM outperformed the casting-based methods (Ti-resin and Ti-wax) in terms of accuracy and defect reduction. These digital approaches may improve the reproducibility and precision of clinical fabrication of CP-Ti RPD frameworks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumComputer-Aided DesignDenture, Partial, RemovableDenture DesignDental MaterialsSurface PropertiesDental Casting TechniquePrinting, Three-DimensionalX-Ray Diffraction

Stichwörter der Autor:innen

CAD-CAMCommercially pure titaniumRemovable partial dentures

Substanzen

TitaniumDental Materials

Autor:innen und Institutionen

  • Department of Removable Partial Prosthodontics, Tokyo Dental College, Tokyo, Japan.
  • Wada Precision Dental Laboratories Company, Osaka, Japan.

Zitieren

APA

Ito, K., Tasaka, A., Kobayashi, H., Nakata, S., & Yamashita, S. (2026). Evaluation of CAD-CAM methods for fabrication of removable partial denture frameworks from commercially pure titanium. Journal of Prosthodontic Research, 70(4), 652-662. https://doi.org/10.2186/jpr.jpr_d_25_00209

Vancouver

Ito K, Tasaka A, Kobayashi H, Nakata S, Yamashita S. Evaluation of CAD-CAM methods for fabrication of removable partial denture frameworks from commercially pure titanium. Journal of Prosthodontic Research. 2026;70(4):652-662. doi:10.2186/jpr.jpr_d_25_00209

BibTeX
@article{Ito2026,
  author = {Ito, Kosei and Tasaka, Akinori and Kobayashi, Hiro and Nakata, Seiichi and Yamashita, Shuichiro},
  title = {Evaluation of CAD-CAM methods for fabrication of removable partial denture frameworks from commercially pure titanium},
  journal = {Journal of Prosthodontic Research},
  year = {2026},
  volume = {70},
  number = {4},
  pages = {652--662},
  doi = {10.2186/jpr.jpr_d_25_00209}
}
Kostenlos starten →