Effect of finishing and polishing techniques on the fit accuracy and dimensions of conventional and CAD‐CAM removable partial denture frameworks
Journal of Prosthodontics · 2026
DOI: 10.1111/jopr.13950 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, 2026. Verfasst von Majed S Altoman und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia. Hauptthemen laut MEDLINE: Computer-Aided Design, Denture, Partial, Removable, Denture Design, Dental Polishing. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
Purpose
The purpose of this study was to compare the effects of finishing and polishing techniques on the fit accuracy, metal loss, and surface roughness of conventional versus CAD‐CAM removable partial denture (RPD) frameworks. Materials and Methods A 3D‐printed maxillary Kennedy class III modification I model served as the master cast. Forty impressions (20 conventional and 20 digital) were divided into four groups: lost‐wax technique (Group I: LWT), CAD‐printed (Group II: CAD‐RP), CAD‐printed from a stone cast (Group III: CAD‐RPS), and lost‐wax technique from resin‐printed models (Group IV: LWTR). Various finishing and polishing techniques were applied, followed by digital scanning for fit accuracy assessment using surface matching software. Metal thickness loss and surface roughness were evaluated pre‐ and post‐finishing and polishing. The Kruskal‐Wallis test followed by the Scheffe post‐hoc test were conducted to evaluate the fit accuracy between groups ( α = 0.05).
Results
Color mapping revealed significant differences ( p < 0.001) between conventionally casted RPD frameworks and 3D‐printed groups post‐finishing and polishing. The most significant gap was observed with the guide plates from printed RPD frameworks. The D‐Lyte technique resulted in less metal loss compared to the conventional finishing and polishing technique ( p < 0.001).
Conclusion
Within the limitations of this study, conventionally processed RPD groups exhibited better overall fit accuracy post‐finishing and polishing. Both conventional cast and 3D‐printed RPD frameworks showed clinically acceptable fit accuracy. The D‐Lyte technique presented less metal loss and smoother surfaces compared to other groups, suggesting it as a viable alternative.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
- Private Practice, Anaheim Hills, California, USA.
- General Dentistry, School of Dentistry, Loma Linda University, Loma Linda, California, USA.
- Advanced Education Program in Prosthodontics, and Center for Dental Research, School of Dentistry, Loma Linda University, Loma Linda, California, USA.
ORCID-Profile: Majed S Altoman, Pooya Soltanzadeh, Montry S Suprono, Thrya S Gadah, Mathew T Kattadiyil
Zitieren
APA
Altoman, M. S., Soltanzadeh, P., Suprono, M. S., Gadah, T. S., & Kattadiyil, M. T. (2026). Effect of finishing and polishing techniques on the fit accuracy and dimensions of conventional and CAD‐CAM removable partial denture frameworks. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13950
Vancouver
Altoman MS, Soltanzadeh P, Suprono MS, Gadah TS, Kattadiyil MT. Effect of finishing and polishing techniques on the fit accuracy and dimensions of conventional and CAD‐CAM removable partial denture frameworks. Journal of Prosthodontics. 2026. doi:10.1111/jopr.13950
BibTeX
@article{Altoman2026,
author = {Altoman, Majed S and Soltanzadeh, Pooya and Suprono, Montry S and Gadah, Thrya S and Kattadiyil, Mathew T},
title = {Effect of finishing and polishing techniques on the fit accuracy and dimensions of conventional and CAD‐CAM removable partial denture frameworks},
journal = {Journal of Prosthodontics},
year = {2026},
doi = {10.1111/jopr.13950}
}
EUVIMED