Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Maria Cristina Pereira Macario Ferreira und 5 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate student, Prosthodontic Department, University of São Paulo (USP), São Paulo, Brazil. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Denture, Partial, Removable, Computer-Aided Design, Denture Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The computer-aided design and computer-aided manufacturing (CAD-CAM) of removable partial denture (RPD) frameworks provides a cost-effective alternative to conventional techniques. However, the accuracy of printed patterns can be influenced by printing parameters and storage conditions, leading to distortions that may compromise RPD retention and longevity. PURPOSE: The purpose of this in vitro study was to evaluate the effects of printing parameters (layer thickness and support diameter) and storage conditions (storage after 7 days and light exposure) on the trueness of 3-dimensionally (3D) printed RPD frameworks by digital superimposition. MATERIAL AND METHODS: A Kennedy Class II modification 2 maxillary cast was scanned to design an RPD framework. Frameworks were printed in castable resin with a digital light processing printer using 25- or 50-µm layers and 200- or 600-µm supports (n=6 per group). Half of the specimens underwent 7 days of storage in a light box simulating daylight; the others were kept in a lightproof box for the same time. Frameworks were scanned immediately after printing and after storage, and deviations at 12 locations were calculated by superimposing the scans onto the original design. The 2-way ANOVA with the Tukey post hoc test was applied (α=.05). RESULTS: Trueness varied across framework locations and was significantly influenced by layer thickness and support diameter (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalDenture, Partial, RemovableComputer-Aided DesignDenture DesignHumansTime FactorsLightSurface Properties

Autor:innen und Institutionen

  • Postgraduate student, Prosthodontic Department, University of São Paulo (USP), São Paulo, Brazil.
  • Postgraduate student, Prosthodontic Department, University of São Paulo (USP), São Paulo, Brazil. Electronic address: yolanda.ressu@alumni.usp.br.
  • Professor, Prosthodontic Department, University of São Paulo (USP), São Paulo, Brazil.

Zitieren

APA

Ferreira, M. C. P. M., Ressurreição, Y. T. S. D., Gomes, R. D., Costa, B., Stegun, R. C., & Mukai, M. K. (2026). Trueness of 3D printed removable partial denture frameworks: Investigation of printing parameters and storage conditions. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.02.005

Vancouver

Ferreira MCPM, Ressurreição YTSD, Gomes RD, Costa B, Stegun RC, Mukai MK. Trueness of 3D printed removable partial denture frameworks: Investigation of printing parameters and storage conditions. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.02.005

BibTeX
@article{Ferreira2026,
  author = {Ferreira, Maria Cristina Pereira Macario and Ressurreição, Yolanda de Toledo Salvado da and Gomes, Rodrigo Diniz and Costa, Bruno and Stegun, Roberto Chaib and Mukai, Marcio Katsuyoshi},
  title = {Trueness of 3D printed removable partial denture frameworks: Investigation of printing parameters and storage conditions},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2026.02.005}
}
Kostenlos starten →