Strain analysis in posterior implant-supported fixed dental prostheses – cemented compared to screwed: An in vitro study
Dental and Medical Problems · 30.06.2026 · (3) · 685-693
DOI: 10.17219/dmp/193568 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Dental and Medical Problems, online erschienen am 30.06.2026. Verfasst von Sarit Naishlos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Dentistry, Tel Aviv University, Israel. Hauptthemen laut MEDLINE: Dental Prosthesis, Implant-Supported, Dental Stress Analysis. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
BACKGROUND: Research on the etiology of excessive strain at the implant neck, which may be associated with technical and biological complications, is still lacking. OBJECTIVES: This in vitro study aimed to compare strain development at the implant neck between cementretained and screw-retained implant-supported fixed restorations, as well as among 3 prosthesis designs, using strain gauge analysis. MATERIAL AND METHODS: Six prosthetic configurations were fabricated and divided according to their retention mechanism: single crowns - cement-retained and screw-retained (SC-c and SC-s, respectively); splinted restorations - cement-retained and screw-retained (SP-c and SP-s, respectively); and simple threeunit bridges - cement-retained and screw-retained (SB-c and SB-s, respectively). Two strain gauges were attached to the implant necks. A vertical load of 200 N was applied simultaneously at 3 identical loading points on each restoration. Strain measurements were analyzed statistically using ANOVA and Scheffé's post hoc contrast analysis. RESULTS: Cement-retained restorations transferred significantly less cervical strain to the implant neck than screw-retained restorations in all 3 prosthetic configurations tested (p < 0.001; SC-c < SC-s; SP-c < SP-s; and SB-c < SB-s). Single crowns transferred significantly less strain to the implant neck than the other restoration designs in both cement-retained and screw-retained groups (p < 0.001; SC-c < SP-c and SB-c; SC-s < SP-s and SB-s). CONCLUSIONS: The use of cement-retained implant-supported fixed prostheses results in less strain development at the implant neck when subjected to high occlusal loads as compared to screw-retained prostheses. Splinting the adjacent implant-supported restorations does not necessarily reduce strain at the implant neck.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pediatric Dentistry, Tel Aviv University, Israel.
- Department of Prosthodontics, Tel Aviv University, Israel.
- Department of Periodontology, Tel Aviv University, Israel.
Zitieren
APA
Naishlos, S., Nissan, J., Shely, A., Ben-Izhack, G., Chaushu, L., & Rosner, O. (2026). Strain analysis in posterior implant-supported fixed dental prostheses – cemented compared to screwed: An in vitro study. Dental and Medical Problems, 685-693. https://doi.org/10.17219/dmp/193568
Vancouver
Naishlos S, Nissan J, Shely A, Ben-Izhack G, Chaushu L, Rosner O. Strain analysis in posterior implant-supported fixed dental prostheses – cemented compared to screwed: An in vitro study. Dental and Medical Problems. 2026:685-693. doi:10.17219/dmp/193568
BibTeX
@article{Naishlos2026,
author = {Naishlos, Sarit and Nissan, Joseph and Shely, Asaf and Ben-Izhack, Gil and Chaushu, Liat and Rosner, Ofir},
title = {Strain analysis in posterior implant-supported fixed dental prostheses – cemented compared to screwed: An in vitro study},
journal = {Dental and Medical Problems},
year = {2026},
number = {3},
pages = {685--693},
doi = {10.17219/dmp/193568}
}
EUVIMED