EUVIMEDEUVIMED entdecken
Vergleichsstudie

An in vitro comparative study on cyclic fatigue resistance of abutment screws in screw‐retained and cement‐retained long single molar crowns

Amulya Jain iD, Purnendu Bhushan, Anjana Raut iD, Sadananda Hota, Arun Mohanty iD, Brundaban Beriha

Journal of Prosthodontics · 2025

DOI: 10.1111/jopr.70083 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Amulya Jain und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Crown & Bridge, Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, India. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis Retention, Dental Abutments, Dental Prosthesis, Implant-Supported. Die Arbeit nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The present study was conducted to assess the cyclic fatigue resistance of implant‐supported long single crowns and the effect of retention type on their mechanical behavior. The investigation aimed at evaluating failure modes and fracture resistance under conditions simulating mastication. Materials and Methods Thirty implant‐supported crowns were made, out of which 15 were screw‐retained and 15 were cement‐retained implant prostheses. The samples were tested on cyclic fatigue loading in a universal testing machine using physiological masticatory forces. The test method adhered to ISO 14801 guidelines, where cyclic loading at 275 N was used at a frequency of 5 Hz until failure or up to 5 million cycles. Fractographic analysis was carried out using FESEM. Statistical analysis was done using the independent t ‐test for fatigue resistance between groups.

Results

Screw‐retained prostheses demonstrated a greater mean number of cycles to screw fracture (105,430 cycles) than cement‐retained prostheses (87,039 cycles), and the difference was not statistically significant ( p = 0.503). Screw‐retained crowns demonstrated greater fatigue resistance at the expense of increased screw loosening. Cement‐retained crowns demonstrated lower fatigue resistance but improved stability. Fractographic analysis verified fatigue fractures with characteristic failure modes between retention types.

Conclusion

Screw‐retained crowns and cement‐retained crowns have statistically insignificant differences in fatigue resistance. Screw‐retained crowns are subject to loosening of the screw, whereas cement‐retained crowns are more stable. The choice of retention type should be based on mechanical performance and clinical retrievability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CrownsDental Prosthesis RetentionDental AbutmentsDental Prosthesis, Implant-SupportedDental Stress AnalysisDental Restoration FailureHumansMaterials TestingMolarDental CementsIn Vitro TechniquesBone ScrewsDental Implant-Abutment DesignStress, Mechanical

Stichwörter der Autor:innen

cyclic fatiguefailure modesfracture resistanceimplant‐supported crownsprosthodontics

Substanzen

Dental Cements

Autor:innen und Institutionen

  • Department of Prosthodontics and Crown & Bridge, Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, India.
  • Central Research Facility, KIIT Deemed to be University, Bhubaneswar, India.

ORCID-Profile: Amulya Jain, Anjana Raut, Arun Mohanty

Zitieren

APA

Jain, A., Bhushan, P., Raut, A., Hota, S., Mohanty, A., & Beriha, B. (2025). An in vitro comparative study on cyclic fatigue resistance of abutment screws in screw‐retained and cement‐retained long single molar crowns. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70083

Vancouver

Jain A, Bhushan P, Raut A, Hota S, Mohanty A, Beriha B. An in vitro comparative study on cyclic fatigue resistance of abutment screws in screw‐retained and cement‐retained long single molar crowns. Journal of Prosthodontics. 2025. doi:10.1111/jopr.70083

BibTeX
@article{Jain2025,
  author = {Jain, Amulya and Bhushan, Purnendu and Raut, Anjana and Hota, Sadananda and Mohanty, Arun and Beriha, Brundaban},
  title = {An in vitro comparative study on cyclic fatigue resistance of abutment screws in screw‐retained and cement‐retained long single molar crowns},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.70083}
}
Kostenlos starten →