Long‐term retention and survival of cemented implant‐supported zirconia and metal‐ceramic single crowns: A retrospective study

P Rammelsberg, A L Klotz iD

Clinical Oral Implants Research · 2024

DOI: 10.1111/clr.14321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2024. Verfasst von P Rammelsberg und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Dental School, University of Heidelberg, Heidelberg, Germany. Hauptthemen laut MEDLINE: Zirconium, Crowns, Dental Prosthesis, Implant-Supported, Dental Restoration Failure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the effect of different cement types on the incidence of failure and loss of retention of zirconia and metal‐ceramic single crowns (SCs) cemented on implant abutments.

Methods

We placed 567 implant‐supported SCs in 358 patients and retrospectively evaluated long‐term retention for up to 12.8 years. The frameworks were made from metal alloy ( n = 307) or zirconia ( n = 260). SCs were cemented with permanent (glass‐ionomer cement; n = 376) or semipermanent cement (zinc oxide non‐eugenol cement; n = 191) on standardized ( n = 446) or customized ( n = 121) abutments. Kaplan–Meier curves were used to calculate the incidence of decementation. Differences between survival curves were assessed with log‐rank tests. Cox‐regression analysis was performed to evaluate multiple risk factors.

Results

Of the 567 SCs, 22 failed because of technical complications and four because of implant loss. Loss of retention was observed in 50 SCs. Analysis revealed a 7% probability of loss of retention for zirconia and 16% for metal‐ceramic SCs after 10 years ( p = .011). After 5 years, loss of retention was higher for standardized abutments than for customized abutments ( p = .014). The probability of loss of retention was higher with semipermanent than with permanent cement ( p = .001). Cox‐regression analysis revealed semipermanent cement as the only significant risk factor for SC failure ( p = .026).

Conclusions

In contrast to semipermanent cement, permanent cement provides acceptable long‐term retention of cemented implant‐supported SCs. These possible positive effects of customized abutments have to be controlled with larger sample sizes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZirconiumCrownsDental Prosthesis, Implant-SupportedDental Restoration FailureHumansRetrospective StudiesFemaleMaleMiddle AgedAdultDental Prosthesis RetentionMetal Ceramic AlloysAgedDental CementsGlass Ionomer CementsDental AbutmentsCementation

Stichwörter der Autor:innen

complicationsimplantloss of retentionsingle crownzirconia

Substanzen

Zirconiumzirconium oxideMetal Ceramic AlloysDental CementsGlass Ionomer Cements

Autor:innen und Institutionen

  • Department of Prosthodontics, Dental School, University of Heidelberg, Heidelberg, Germany.

ORCID-Profile: A L Klotz

Zitieren

APA

Rammelsberg, P., & Klotz, A. L. (2024). Long‐term retention and survival of cemented implant‐supported zirconia and metal‐ceramic single crowns: A retrospective study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14321

Vancouver

Rammelsberg P, Klotz AL. Long‐term retention and survival of cemented implant‐supported zirconia and metal‐ceramic single crowns: A retrospective study. Clinical Oral Implants Research. 2024. doi:10.1111/clr.14321

BibTeX
@article{Rammelsberg2024,
  author = {Rammelsberg, P and Klotz, A L},
  title = {Long‐term retention and survival of cemented implant‐supported zirconia and metal‐ceramic single crowns: A retrospective study},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  doi = {10.1111/clr.14321}
}