EUVIMEDEUVIMED entdecken
Vergleichsstudie

Effect of different surface treatments on the retention force of additively manufactured interim implant‐supported crowns

Thaleia Filokyprou iD, Matthew J Kesterke iD, Xiaohua Liu, Seok-Hwan Cho iD, Marta Revilla-León iD

Journal of Prosthodontics · 2024-12 · 33 (9) · 899-907

DOI: 10.1111/jopr.13783 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, online erschienen am 03.11.2023. Verfasst von Thaleia Filokyprou und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis, Implant-Supported, Surface Properties, Dental Prosthesis Retention. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Texas A and M University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the effect of different pre‐cementation surface treatments and bonding protocols on the retention force of additively manufactured (AM) implant‐supported interim crowns. Material and methods A total of 50 AM interim crowns (Temporary CB resin) were cemented on implant abutments. Five groups ( n = 10) were established based on the different surface pre‐treatments performed in the intaglio surface of the specimens: no surface pre‐treatment (Group C or control), air‐abraded with 50‐μm aluminium oxide particles (Group AP) , air‐abraded with 50‐μm aluminium oxide particles followed by the application of silane (Group AMP), silane (Group MP), and air‐abraded with 30 μm silica‐coated aluminum oxide particles followed by the application of silane (Group CMP). Each specimen was cemented into an implant abutment using a composite resin cement (Rely X Unicem2). Afterward, the specimens underwent retention testing with a Universal Instron machine. Pull‐off forces (N) and modes of failure were registered. Statistical analysis was performed using Mann‐Whitney U tests with Bonferroni corrections for multiple tests (α = 0.05).

Results

The median retention force values were 233.27 ±79.28 N for Group Control, 398.59 ±68.59 N for Group MP, 303.21 ±116.80 N for Group AMP, 349.31 ±167.73 N for Group CMP, and 219.85 ± 55.88 N for Group AP. The pull‐off forces were significantly greater for Group MP, while the differences between the remaining groups were not statistically significant ( P > 0.05). Group AP showed the lowest retention force values among all the groups. Failure modes after the pull‐off testing were predominantly adhesive and substrate failure of the AM interim material.

Conclusions

The surface treatment of the intaglio AM crown tested significantly influenced the retention force values measured. Pre‐treatment with an MDP‐containing silane improved the retentive force values computed, whereas pre‐treatment with 50‐μm Al 2 O 3 air‐particle abrasion alone is not recommended prior to cementation on a titanium‐based implant abutment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CrownsDental Prosthesis, Implant-SupportedSurface PropertiesDental Prosthesis RetentionDental Stress AnalysisHumansAluminum OxideMaterials TestingDental AbutmentsCementationResin CementsSilanesDental BondingDental Etching

Stichwörter der Autor:innen

3D printingbondingretention forcetemporary crownstitanium base abutments

Substanzen

Aluminum OxideResin CementsSilanes

Autor:innen und Institutionen

  • Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA.
  • Department of Orthodontics, College of Dentistry, Texas A&M University, Dallas, Texas, USA.
  • Department of Biomedical Sciences, College of Dentistry, Texas A&M University, Dallas, Texas, USA.
  • Department of Prosthodontics, College of Dentistry and Dental Clinics, University of Iowa, Iowa City, Iowa, USA.
  • Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.
  • Kois Center, Seattle, Washington, USA.

ORCID-Profile: Thaleia Filokyprou, Matthew J Kesterke, Seok-Hwan Cho, Marta Revilla-León

Förderung

  • Texas A and M University

Zitieren

APA

Filokyprou, T., Kesterke, M. J., Liu, X., Cho, S. H., & Revilla-León, M. (2024). Effect of different surface treatments on the retention force of additively manufactured interim implant‐supported crowns. Journal of Prosthodontics, 33(9), 899-907. https://doi.org/10.1111/jopr.13783

Vancouver

Filokyprou T, Kesterke MJ, Liu X, Cho SH, Revilla-León M. Effect of different surface treatments on the retention force of additively manufactured interim implant‐supported crowns. Journal of Prosthodontics. 2024;33(9):899-907. doi:10.1111/jopr.13783

BibTeX
@article{Filokyprou2024,
  author = {Filokyprou, Thaleia and Kesterke, Matthew J and Liu, Xiaohua and Cho, Seok-Hwan and Revilla-León, Marta},
  title = {Effect of different surface treatments on the retention force of additively manufactured interim implant‐supported crowns},
  journal = {Journal of Prosthodontics},
  year = {2024},
  volume = {33},
  number = {9},
  pages = {899--907},
  doi = {10.1111/jopr.13783}
}
Kostenlos starten →