EUVIMEDEUVIMED entdecken
Crossref

Evaluation Of CAD/CAM Milled Zirconia Crowns And 3D Printed Permanent Resin Crowns in the term of Adaptation

Dalan Jamal Kamal, Fahd Sudad Ikram

Erbil Dental Journal · 30.06.2026 · 9 (1) · 77-87

DOI: 10.15218/edj.2026.9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Erbil Dental Journal, online erschienen am 30.06.2026. Verfasst von Dalan Jamal Kamal und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objective: This study aimed to evaluate and compare the adaptability in term of internal fitting for both types of computer aided design and computer aided milling (CAD/CAM) milled zirconia crown and 3D printed permanent resin crown in both periods of before and after thermocycling aging to evaluate the clinical performance of both types of crowns.

Method

Forty crowns were manufactured: twenty from CAD/CAM zirconia milling group and twenty from 3D-printed permanent resin group. The internal fit test is done for the crowns both before and after thermocycle aging using silicone replica technique. Measurements were taken at marginal, axial, axio-occlusal, and centro-occlusal points under stereomicroscope of 20x magnification. Data analyzed on SPSS software using multiple comparison test.

Result

There were no differences that is statistically significant in most of the points measured for both types of CAD/CAM milled zirconia and 3D-printed permanent resin crown. Thermocycling aging did not result in statistically significant differences for the internal fit of both types of crowns.

Conclusion

Clinically acceptable internal fit values were shown by both 3D-printed permanent resin crowns and CAD/CAM milled zirconia crowns. In some cases of greater adaptation, 3D-printed crowns performed similarly to milled crowns. Thermocycling had no significant impact on internal fit, indicating the materials' and fabrication techniques' long-term clinical practicality. Keywords: Internal fit, adaptation, CAD/CAM milled zirconia crown, 3D printed permanent resin crown

Zitieren

APA

Kamal, D. J., & Ikram, F. S. (2026). Evaluation Of CAD/CAM Milled Zirconia Crowns And 3D Printed Permanent Resin Crowns in the term of Adaptation. Erbil Dental Journal, 9(1), 77-87. https://doi.org/10.15218/edj.2026.9

Vancouver

Kamal DJ, Ikram FS. Evaluation Of CAD/CAM Milled Zirconia Crowns And 3D Printed Permanent Resin Crowns in the term of Adaptation. Erbil Dental Journal. 2026;9(1):77-87. doi:10.15218/edj.2026.9

BibTeX
@article{Kamal2026,
  author = {Kamal, Dalan Jamal and Ikram, Fahd Sudad},
  title = {Evaluation Of CAD/CAM Milled Zirconia Crowns And 3D Printed Permanent Resin Crowns in the term of Adaptation},
  journal = {Erbil Dental Journal},
  year = {2026},
  volume = {9},
  number = {1},
  pages = {77--87},
  doi = {10.15218/edj.2026.9}
}
Kostenlos starten →