Evaluation of the accuracy of conventional and digital implant impression techniques in bilateral distal extension cases: a randomized clinical trial
BMC Oral Health · 05.07.2024 · 24 (1)
DOI: 10.1186/s12903-024-04495-0 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift BMC Oral Health, online erschienen am 05.07.2024. Verfasst von Wafaa Youssef Elashry und 2 weiteren Autor:innen. Beteiligte Einrichtung: Assistant lecturer, Prosthodontic department, Faculty of Dentistry, Tanta University, Tanta, Egypt. Hauptthemen laut MEDLINE: Dental Impression Technique. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tanta University.
Abstract (Originalsprache)
Background
This clinical study aims to evaluate the accuracy of the conventional implant impression techniques compared to the digital impression ones in bilateral distal extension cases.
Methods
A total of 32 implants were placed in eight patients missing all mandibular posterior teeth except the first premolars. Each patient received a total of four implants, with two implants placed on each side, in order to provide support for three units of screw-retained zirconia restorations. Following osteointegration, the same patient underwent two implant-level impression techniques: Conventional open-tray impressions CII (splinted pick-up) and digital implant impressions DII with TRIOS 3 Shape intraoral scanner. The accuracy of impressions was evaluated utilizing a three-dimensional superimposition analysis of standard tessellation language (STL) files. Subsequently, the scan bodies were segmented using Gom inspect software to measure three-dimensional deviations in a color-coding map. Data were statistically analyzed using the Kruskal Wallis test and then a post-hoc test to determine the significance level ( P < 0.05).
Results
The study revealed that higher angular and positional deviations were shown toward distal scan bodies compared to mesial ones for both impression techniques. However, this difference was not statistically significant ( P > 0.05).
Conclusion
Splinted open-tray conventional impression and intraoral scanning implant impression techniques have demonstrated comparable accuracy.
Trial registration
Clinical Trials.gov Registration ID NCT05912725. Registered 22/06/ 2023- Retrospectively registered , https://register.clinicaltrials.gov .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Assistant lecturer, Prosthodontic department, Faculty of Dentistry, Tanta University, Tanta, Egypt.
- Professor, Prosthodontic department, Faculty of Dentistry, Tanta University, Tanta, Egypt. mohamed.elshaikh@dent.tanta.edu.eg.
- Professor, Prosthodontic department, Faculty of Dentistry, Tanta University, Tanta, Egypt.
Förderung
- Tanta University
Zitieren
APA
Elashry, W. Y., Elsheikh, M. M., & Elsheikh, A. M. (2024). Evaluation of the accuracy of conventional and digital implant impression techniques in bilateral distal extension cases: a randomized clinical trial. BMC Oral Health, 24(1). https://doi.org/10.1186/s12903-024-04495-0
Vancouver
Elashry WY, Elsheikh MM, Elsheikh AM. Evaluation of the accuracy of conventional and digital implant impression techniques in bilateral distal extension cases: a randomized clinical trial. BMC Oral Health. 2024;24(1). doi:10.1186/s12903-024-04495-0
BibTeX
@article{Elashry2024,
author = {Elashry, Wafaa Youssef and Elsheikh, Mohamed Maamoun and Elsheikh, Ali Mohamed},
title = {Evaluation of the accuracy of conventional and digital implant impression techniques in bilateral distal extension cases: a randomized clinical trial},
journal = {BMC Oral Health},
year = {2024},
volume = {24},
number = {1},
doi = {10.1186/s12903-024-04495-0}
}
EUVIMED