Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses
Journal of Prosthodontic Research · 2023
DOI: 10.2186/jpr.jpr_d_22_00242 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Prosthodontic Research, 2023. Verfasst von Yun Ma und 3 weiteren Autor:innen. Beteiligte Einrichtung: Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian …. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Prosthesis, Implant-Supported, Dental Implants, Mouth. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 54 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To compare the trueness and precision of different impression techniques for two-implant-supported fixed dental prostheses between extraoral and intraoral conditions at different locations. METHODS: Six volunteers participated in this study. A resin block with two parallel analogs was fabricated as an implant site simulator (ISS). The ISS was bonded to a molded ethylene vinyl acetate sheet to create a reference model. For each participant, four reference models were prepared based on the locations of the ISSs: maxillary posterior/anterior region (MaxP/MaxA) and mandibular posterior/anterior region (ManP/ManA). Five impressions were taken extraorally using the open-tray (conventional implant impression technique, CIT) and intraoral scanning (digital implant impression technique, DIT) techniques. The reference models were positioned in the participants' mouths, and impressions were obtained intraorally using the CIT and DIT. The interanalog distance (d) and angulation (θ) were measured to calculate trueness (Δd, Δθ) and precision (dP, θP). Two-way ANOVA and t tests were performed (α=0.05). RESULTS: For the DIT, under intraoral conditions, the Δd and Δθ in MaxP and Δθ in ManP were significantly higher than those under extraoral conditions. For the CIT, under intraoral conditions, the Δd and Δθ in ManA and ManP and Δθ in MaxP were significantly lower than those under extraoral conditions. No significant differences in the dP and θP of either DIT or CIT were observed between the two conditions. CONCLUSIONS: Intraoral conditions affected the trueness of DIT and CIT in different regions but had no influence on precision.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Med…
- Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, Fuzhou, China.
- Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan.
Zitieren
APA
Ma, Y., Guo, Y. Q., Jiang, L., & Yu, H. (2023). Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses. Journal of Prosthodontic Research. https://doi.org/10.2186/jpr.jpr_d_22_00242
Vancouver
Ma Y, Guo YQ, Jiang L, Yu H. Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses. Journal of Prosthodontic Research. 2023. doi:10.2186/jpr.jpr_d_22_00242
BibTeX
@article{Ma2023,
author = {Ma, Yun and Guo, Yong-Qing and Jiang, Lei and Yu, Hao},
title = {Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses},
journal = {Journal of Prosthodontic Research},
year = {2023},
doi = {10.2186/jpr.jpr_d_22_00242}
}
EUVIMED